  5.4 DMX512 Configuration   

 

 

Ch 1 

Ch 2 

Ch 3 

Ch 4 

Ch 5 

Ch 6 

Ch 7 

IM-5S Pan  Tilt  Shutter/Sharking  Gobo 

Color  

 

IM-5W 

Pan 

Tilt 

Shutter 

No function 

Color 

No function 

Dimmer

Stand by 

Blackout the unit 

Function 

Strobe 
1.Gobo/Color sync

strobe 

2.Sync. strobe 
3.Two-light strobe 

X/Y moving show mode 
selection 
( Show 1 ~ Show 4 ) 
Please refer to Show mode 
in 4.2   Main Function.

.

   

Color/Gobo selection   
1. Hold on for gobo 

change. 

2. Press shortly for 

color change. 

X/Y moving setting 
1.Pan position 
2.Tilt position 
First set Master unit, 
then set Slave units’ 
position.  

IM-5S 

Mode 

Sound 1 
(LED off ) 

Sound 2 
(LED normal blinking) 

Slow/Sound 3 
(LED on) 

Position/ Latch 
(LED fast blinking) 

Stand by 

Blackout the unit 

Function 

Strobe 
1.Gobo/Color sync

strobe 

2.Sync. strobe 
3.Two-light strobe

 

X/Y moving show mode 
selection 
( Show 1 ~ Show 4 ) 
Please refer to Show mode 
in 4.2   Main Function.

.

   

Color selection   

 

X/Y moving setting 
1.Pan position 
2.Tilt position 
3.Dimmer  
First set Master unit, 
then set Slave units’ 
position.

 

IM-5W 

Mode 

Sound 1 
(LED off ) 

Sound 2 
(LED normal blinking) 

Slow/Sound 3 
(LED on) 

Position/ Latch 
(LED fast blinking) 

 
  5.3.1 iSolution Operation 

 

 

 

Consistent DMX configuration enable iMove to be linked together with iRock and iShow 

and controlled at the same time.   

 

DMX address can be set remotely by iLead controller ( please refer to the user manual 

of iLead controller ). No need to calculate the DMX channels of each fixture in the chain.

 

 

  Automatic switching between DMX function and built-in stand alone programs.

 

 

  5.3.2 DMX Controller 

 

If you use a universal DMX controller to control the units, you have to set DMX address from 
1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when 

the display stops blinking or storing automatically 8 seconds later. To go back to the 
functions without any change press the

 MENU

 button again. Please refer to the following 

diagram to address your DMX512 channel for the first 4 units.   
DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX 
channels of each fixture in the chain.   

 

Содержание iSolution IMOVE-5S

Страница 1: ...e 20mm Glass 6 3A Fast Blow 20mm Glass 5A Fast Blow Lamp ELC 24V 250W Dimension 290mm x 330mm x 380mm Weight 12 kg BEGLEC CVA t Hofveld 2 B1702 Groot Bijgaarden WWW BEGLEC COM Innovation Quality Performance IMOVE 5S IMOVE 5W User Guide Professional Entertainment Technology ...

Страница 2: ...with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 1 1993 EN61000 3 2 1995 EN61000 3 3 1995 EN55014 2 1997 CATEGORY II EN61000 4 2 1995 EN61000 4 3 1995 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1995 EN61000 4 11 1994 Harmonized Standard EN60598 1 1993 Safety of household and similar electric...

Страница 3: ...e and screwed it Note do not press the belt 7 Put the belt around the axis gear and motor gear 8 Plug all the connect wires C that form the arm to PC board and ignitor 9 Adjust the pan home position 10 Screw the base housing cover B TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 2 1 Beam Angel 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 5 How To Control The U...

Страница 4: ...pare parts Don t connect the device to any dimmer pack or power pack Do not touch any wire during operation as high voltage might be causing electric shock 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2...

Страница 5: ...o have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Warning To pr...

Страница 6: ...istent DMX channel enable iRock iShow and iMove to be link together Features different preprogrammed chase patterns Please use a 3 pin XLR cable plug when connecting units together Accurate focusable optics system and ultra smooth stepping motors Fan cooling Pan 540 deg Tilt 270 deg Dimension 290 x 330 x 380 mm Weight 12 kg IM 5S Independent gobo wheel with 14 gobos plus open and blackout includin...

Страница 7: ...ing Slow Sound 3 LED on Position Latch LED fast blinking 5 3 1 iSolution Operation Consistent DMX configuration enable iMove to be linked together with iRock and iShow and controlled at the same time DMX address can be set remotely by iLead controller please refer to the user manual of iLead controller No need to calculate the DMX channels of each fixture in the chain Automatic switching between D...

Страница 8: ...ED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microphone jack to control the unit for stand by function and mode Sensitiv...

Страница 9: ...ly 5 2 Easy Controller The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit you will find that the remote control on the first unit will control all the other units for Stand by Strobe Next and Fast Slow function Display Inversion It is good for you to install the unit on the floor or under ceiling Press the MENU button up to when the...

Страница 10: ...8 seconds To go back to the functions without any change press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 mode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angel left to right to left 160 Tilt mov...

Страница 11: ...t any change after 8 seconds To go back to the functions without any change press the MENU button again Tilt Inversion Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or tilt inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main fu...