background image

 

20 

 

DMK SC 016-3C 

1/10/2014 

 

 

 

 

 

[email protected]

 

 

 

 

 

 

www.beewair.com

 

Содержание BW60L

Страница 1: ... DMK SC 016 3C 1 10 2014 BW60L OPERATING MANUAL Ref 109 073 Clinical White Notice traduite de l originale Date de dernière révision 01 10 2014 Ref 109 071 Charcoal Grey Ref 109 072 White Varnished Finish ...

Страница 2: ...2 DMK SC 016 3C 1 10 2014 ...

Страница 3: ...settings 3 3 1 Stop start ventilation speed selection 3 3 2 Automatic or manual mode 3 3 3 LED light levels 3 3 4 Protective fuse 4 Maintenance 4 1 Frequency of replacement 4 2 Filter remove 4 3 Changing the reactor cartridge 4 4 Cleaning 5 Warranty 5 1 Warranty length 5 2 Warranty terms 6 Environmental Protection 7 Contacts 8 WEEE Directive 9 CE Conformity ...

Страница 4: ...4 DMK SC 016 3C 1 10 2014 ...

Страница 5: ...atic shock Risk of UV radiation Read the instructions Waste of electrical or electronic equipment Grounding mass Modèle BW 60L G Réf 109 071 Système de traitement de l air Technologie DBD Lyse BEEWAIR Made in France Fabriquant BEEWAIR 3 allée de la Teppe BP60031 71012 MACON CEDEX FRANCE N de série Date de Fabrication Alimentation AC 230V 50Hz Consommation 40 Watts Fusibles 1 25AT 250V Model Device...

Страница 6: ...Warning it is prohibited to modify the unit in any way Any modification could damage the device or render it dangerous to others Repairs or unit maintenance should only be carried out by a qualified person In case of malfunctioning immediately switch the device off and unplug it Then please contact the after sales service Risk of electromagnetic interference This device conforms to EMC tests accor...

Страница 7: ...ntaminants viruses bacteria smells allergans VOCs etcBthrough a physical chemical method A photo catalytic electrical discharge barrier generates free radicals which instantaneously degrade all carbon chains of the molecules inside the reactor and then recompose into stable molecules which can be found naturally in water H O or air oxygen O nitrogen N and carbondioxyde CO ...

Страница 8: ...organic odors Dimensions Height 65 cm Width 24 cm Depth 16 cm Weight 9 5 Kg Power Supply Model 109 071 and 109 072 220 230 Volts AC 50Hz Model 109 073 110 230 Volts AC 50 60Hz Power consumption Model 109 071 and 109 072 40 Wh Model 109 073 90Wh Absorbed power Model 109 071 and 109 072 42VA Model 109 073 93VA Fuses 5 20mm T1 25A H 250V Maintenance DBD Lyse Module 20 000 hours 2 years Pre filters ev...

Страница 9: ...9 DMK SC 016 3C 1 10 2014 1 Stop start ventilation speed selection 2 Manuel Mode 3 LED light switch 4 Transport handle 1 2 3 Air output Air input 1 2 3 4 ...

Страница 10: ...e sure that the line voltage in the room where the unit will be installed complies with the specifications listed on the material safety data sheet The unit must be installed in a clean ventilated room on a flat clear surface within normal temperature atmospheric pressure and humidity ranges Do not install the unit in such manner that the air entry and air outlet can be blocked or restricted Trans...

Страница 11: ...reatment according to the level of pollution detected In manual mode you can regulate the air treatment according to your own personal needs time restrictions specific pollution sources odours etc In automatic mode Position speed 1 The probe controls the start of air treatment in low speed Position speed 2 The probe controls the start of air treatment and moves to high speed when any pollution is ...

Страница 12: ...sensor Then once the probe detects an increase in the pollution level 12ppm 12ppm 27ppm 27ppm 40 40 90 90 LED Blue LED Orange LED Red When the probe detects a decrease in the pollution level 27ppm 12ppm 27ppm 10ppm 90 80 80 35 35 LED Red LED Orange LED Blue The pollution detection probe integrated in the decontamination unit BW60L Beewair controls the visual pollution level indicators LED s The se...

Страница 13: ...ieve the blue level by the probe FAQ The unit never shows a blue light even after a sufficient amount of decontamination time The probe is subjected to a rigorous internal testing The sensors are also 100 tested Verify the dimensions of the space with regard to the capacity of the unit The unit does not ignite Verify the electric connections The unit makes strange noises Turn off the power and on ...

Страница 14: ...unction correctly it is important that the pre filter G4 is changed once a year In the case of very dusty environments it may be necessary to replace it more often The reactor cartridge must be replaced after 20 000 hours use or every 2 years 4 2 Filter removal Fuse drawer Security fuse Spare fuse ...

Страница 15: ... technician only and Beewair recommends to contactor your official distributor in order to arrange this maintenance procedure During the reactor cartridge exchange the operator should use anti UV C protective equipment It is absolutely required to cut the power supply before any maintenance operation 4 4 Cleaning The device must be cleaned regularly using a soft wet cloth or a smooth cleaner It is...

Страница 16: ...e covered for 1 year from date of invoice 5 2 Terms of warranty The warranty applies to all parts of the unit except consumables which must be changed regularly Any manufacturing defect in the unit is covered under warranty only if the unit has been used strictly for air treatment purposes Use of the unit for any other purpose will void the warranty 6 Environmental protection Environmental protect...

Страница 17: ...ut this number the after sales department will not be able to repair the device Please have the serial number of your unit on hand label on the rear panel before you call THE AFTER SALES DEPARTMENT WILL NOT ACCEPT A PART OR UNIT FOR RETURNS WITHOUT A PRE ISSUED RETURN NUMBER Made by BEEWAIR Address BP 60031 71012 Mâcon Cedex France Tel 33 0 3 85 36 00 73 Fax 33 0 9 70 32 08 66 E mail contact beewa...

Страница 18: ...eparate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this form other types of wastes and recycle it responsibly to promote the sustainable reuse of material resource...

Страница 19: ...19 DMK SC 016 3C 1 10 2014 9 CE Conformity ...

Страница 20: ...20 DMK SC 016 3C 1 10 2014 contact beewair fr www beewair com ...

Отзывы: