12
NATURAL GAS CONVERSION
GAS CONVERSION
Natural gas installation
NOTE: Conversion of this unit to natural gas must be
carried out by a qualifed licenced person and a Certificate of
Compliance must be issued to the owner on completion of
the insatllation conversion.’
Converting to natural gas (to the installer)
This barbecue is supplied set up for Universal LPG and is
labelled accordingly. Anatural gas conversion kit is available
as an accessory by contacting Electrolux customer service.
1 x Natural gas hose and regulator assembly with quick
connect bayonet fitting.
1 x bag containing:
5 x 45° valve with 1.90mm injectors
1 x 90° valve with 1.80mm injector
1 x Natural gas label
Procedure
1. Remove knobs and for each bezel remove 2 screws
retaining the bezel to the valve.
2. At each end of the control panel, remove 3 screws
retaining the control panel.
K n o b
S c r e w
3. Remove control panel to access the valves
4. Remove each valve and replace with valve provided in
the natural gas conversion kit, note the injector size, as
shown on page 14.
Knob
Control
panel
Valve screw
Screw
Screw
5. Remove the hose and regulator assembly, and replace the
hose and regulator appropriate for the intended gas supply.
6. Turn on gas & check for leaks at every connection (use
soap solution to identify leaks.)
7. Replace the control panel, bezels and the knobs.
8. Check and adjust if necessary the supply pressure is
1.13kPa.
9. The operation of the regulator can be confirmed by
connecting a manometer to the test point located on the
side of the regulator body. With three burners operating
at maximum the outlet pressure should measure 1.0kPa.
Side burner valve
Содержание DISCOVERY 1000E SERIES
Страница 1: ...Assembly and Operating Instructions FOR OUTDOOR USE ONLY DISCOVERY 1000E SERIES AUSTRALIA NEW ZEALAND ...
Страница 21: ...21 NOTES NOTES ...
Страница 22: ...22 NOTES NOTES ...