BEDU SPA 11 Series Скачать руководство пользователя страница 3

GB

THIS INSTRUCTION MANUAL IS THE PROPERTY 

OF 

BEDU POMPEN

ANY REPRODUCTION, EVEN 

IF PARTIAL, IS FORBIDDEN

1. GENERAL INFORMATION

Before using the product carefully read the information 

contained in this instruction manual, the manual should 

be kept for future reference.

Italian is the original language of this instruction

manual, this language is the reference language in 

case of discrepancies in the translations.

This manual is part of the essential safety requirement

and  must  be  retained  until  the  product  is  finally  de-

commissioned.

The customer, in case of loss, can request a copy

of the manual by contacting 

Bedu Pompen BV

 or their 

agent, specifying the type of product data shown on 

the label of the machine (see 2.3 Marking)

Any changes, alterations or modifications made to the

product or part of it, not authorized by the manufacturer, 

will revoke the “CE declaration” and warranty.

This appliance should not be operated 

by children younger than 8 years, 

people with reduced physical, sensory 

or mental capacities, or inexperienced 

people who are not familiar with the 

product, unless they are given close 

supervision or instructions on how to 

use it safely and are made aware by 

a responsible person of the dangers 

its use might entail. Children must not 

play with the appliance.

It is the user's responsibility to clean 

and maintain the appliance. Children 

should never clean or maintain it 

unless they are given supervision.

Read carefully the installation 

section which sets forth:

-  The maximum permissible structural 

working pressure (chapter 3.1). 

-  

The type and section of the

power cable (chapter 6.5).

-  The type of electrical protection

to be installed (chapter 6.5).

1.1. Symbols

To improve the understanding of the manual, below are 

indicated the symbols used with the related meaning.

 

 

Information and warnings that must be 

observed, otherwise there is a risk that the 

machine could damage or compromise 

personnel safety.

The failure to observe electrical information 

and warnings, could damage the machine or 

compromise personnel safety.

i

  Notes and warnings for the correct management 

of the machine and its parts.

   Operations that could be performed by the final 

user. After carefully reading of the instructions, 

is responsible for maintenance under normal 

conditions. They are authorized to affect 

standard maintenance operations.

Operations that must be performed by a 

qualified  electrician.  Specialized  technician 

authorised to affect all electrical operations 

including maintenance. They are able to 

operate with in the presence of high voltages.

 Operations that must be done performed by 

a  qualified  technician.  Specialized  technician 

able to install the device, under normal 

conditions, working during “maintenance”, 

and allowed to do electrical and mechanical 

interventions for maintenance. They must 

be capable of executing simple electrical 

and mechanical operations related to the 

maintenance of the device.

 Indicates that it is mandatory to use individual 

protection devices.

OFF

  Operations that must be done with the device 

switched off and disconnected from the power 

supply.

ON

  Operations that must be done with the device 

switched on.

1.2. Manufacturer name and address

1.3. Authorized operators

The product is intended for use by expert operators 

divided into end users and specialized technicians. 

(see the symbols above).

i

  It’s  forbidden,  for  the  end  user,  carry  out

operations which must be done only by 

specialized technicians. The manufacturer 

declines any liability  for damage related to the 

non-compliance of this warning.

1.4. Warranty

For the product warranty refer to the general terms and 

conditions of sale. 

SUMMARY

1.

GENERAL INFORMATION 

2.

TECHNICAL DESCRIPTION 

3.

TECHNICAL FEATURES 

4.

SAFETY 

5.  TRANSPORTATION AND HANDLING 

6.

INSTALLATION 

7.

STARTUP AND OPERATION 

8.

MAINTENANCE 

9.

DISPOSAL 

10. SPARE PARTS 

11. ESIGNATION OF PARTS 

12. TROUBLESHOOTING 

Drawing for dismantling and assembly .

Declaration of conformity 

SPA Rev7.indd   8

08/02/19   17:46

 Bedu Pompen B.V. 

Poort van Midden Gelderland Rood 10 

6666 LT  HETEREN, The Netherlands 

 

Содержание SPA 11 Series

Страница 1: ... Self draining whirlpool pumps OPERATING INSTRUCTIONS SPA ...

Страница 2: ...SPA Rev7 indd 1 08 02 19 17 46 ...

Страница 3: ...The failure to observe electrical information and warnings could damage the machine or compromise personnel safety i Notes and warnings for the correct management of the machine and its parts Operations that could be performed by the final user After carefully reading of the instructions is responsible for maintenance under normal conditions They are authorized to affect standard maintenance opera...

Страница 4: ...talogue Nominal speed 2900 3450 rpm Protection IP X5 Supply voltage Frequency up to 240V 1 50 60 Hz up to 480V 3 50 60 Hz Check that the mains frequency and voltage correspond to the electrical characteristics shown on the indicator plate The electric data marked on the label are referred to the nominal power of the motor Sound pressure 70 dB A Max starts per hour 30 at regular intervals Maximum p...

Страница 5: ...t remain in the system after the tub has been drained To allow for self draining mount the pump on a base positioned at a level equal to or higher than the bathtub or spa suction port and to allow for filling with the delivery port positioned at a level lower than that for normal filling under the overflow discharge Installation beneath the skirt of a bathtub or spa which is closed externally with...

Страница 6: ...aft by hand only in the direction indicated by the arrows on the pump casing Note that a slight degree of resistence to rotation is normal this is due to friction caused by the mechanical seal The pump might be jammed by an obstruction foreign matter sticking of mechanical seal surfaces or other causes If the shaft cannot be freed by hand the pump will have to be dismantled and cleaned With three ...

Страница 7: ...spring right down as far as the front shoulder In this way correct spring compression will be ensured in subsequent assembly Lubricate the seal with water and align the impeller on the motor shaft ATTENTION with the three phase models to avoid the unscrewing and breaking of the impeller should the motor start rotating backwards clean the threaded shaft end and apply on the first half of the thread...

Страница 8: ...See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of the rotor 4c Rotor deteriorated 4d Worn rotor and pump case 4e Excessive viscosity of the liquid pumped if other than water 4f Incorrect direction of rotation 4g Suction head excessive in relation to the suction ca...

Страница 9: ...4 00 90 00 88 00 82 04 81 00 76 16 92 00 78 00 76 00 73 00 73 08 36 00 14 24 14 29 14 28 27 04 76 50 70 00 14 20 27 00 28 00 27 08 14 00 36 00 14 24 14 29 14 28 27 04 98 04 94 00 98 08 98 00 76 54 76 04 90 00 90 04 76 00 70 20 73 08 82 04 81 00 78 00 73 00 81 04 82 00 88 00 82 08 76 50 1 Draining hole Д ÂÌ ÊÌÓÂ ÓÚ Â ÒÚËÂ SPA 11 SPA 11 21 A 31 A SPA 41 SPA Rev7 indd 26 08 02 19 17 46 ...

Страница 10: ...urrent of appliance A Corriente nominal del aparato Dimensiestroom van apparaat Номинальный ток прибора 设备额定运行电流 Sezione nominale Nominal cross sectional area Nominal cross sectional area Nominale dwarsdoorsnede Номинальное сечение 导体额定截面积 3 6 10 16 25 32 40 0 75 1 0 1 5 2 5 4 6 10 6 10 16 25 32 40 63 SPA Rev7 indd 27 08 02 19 17 46 ...

Страница 11: ...etic compatibility Standards EN ISO 12100 2010 EN IEC 60204 1 2006 EN 809 A1 C1 Additional information No further details Declaration We hereby declare under our sole responsibility that the product s mentioned above to which this declaration relates complies with the above mentioned standards and Directives BEDU Pompen BV Poort van Midden Gelderland Rood 10 6666 LT Heteren Tel 31 0 88 4802 900 Fa...

Страница 12: ......

Страница 13: ...orking from our own workplace or at your location A fast and appropriate solution for all your issues Wide range of liquid pumps Repair maintenance and revision made for your process BEDU POMPEN B V Poort van Midden Gelderland Rood 10 6666 LT HETEREN Nederland Telefoon 31 0 88 4802 900 E mail info bedu eu WWW BEDU EU BEDU BELGIUM B V B A Industriepark West 75 9100 SINT NIKLAAS België Telefoon 32 0...

Отзывы: