BECKWITH ELECTRIC BlueJay M-2913 Скачать руководство пользователя страница 8

M-2913 BlueJay Wireless Data Transceiver

–8–

Safety and Cautions

8

WARNING

:

 The installation, maintenance, and/or operation of this equipment could present

potentially unsafe conditions, including, but not limited to, electrical shock or improper voltage to
components. Improper operation could cause personal injury, death, or damage to property.

Read all safety instructions before operating the M-2913, and retain them for further reference. Follow all
operating and usage instructions, and make special note of the following safety symbols:

This sign warns that the area is connected to a dangerous high voltage, and you must
never touch it.

This sign means that you should refer to the corresponding section of the operation
manual for important information before proceeding.

Do not attempt to perform maintenance or service functions that are not described in the operating
instructions. Instead, refer all such service requirements to Beckwith Electric Co., Inc. Unit must be returned
for service in secure (preferably original) packaging. Shipping cost must be paid by user.

Only the antenna provided is authorized for use with the M-2913. If the antenna is lost or damaged, please
contact Beckwith Electric Co., Inc. to secure a replacement antenna.

This product generates, uses, and can radiate radio frequency (RF). If it is not installed and used in
accordance with the operating instructions, it can cause harmful interference to communications. If this
equipment causes harmful interference to radio or television reception, the user should try and correct the
interference by:

Reorienting or relocating the receiving/transmitting antenna

Increasing the separation between the equipment and the M-2913

Connecting the equipment into an outlet on a different circuit from the M-2913.

If these do not correct the interference, consult an experienced radio/television technician for assistance.
Correcting such interference is the responsibility of the user, not the manufacturer.

Compliance

This device has been designed to operate with an antenna having a maximum gain of 2 dB. Antenna having
a higher gain are strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50
ohms.

This equipment has been tested and found to comply with the limit requirements, pursuant to Part 15.247 of
the FCC Rules and Industry Canada RSS-210 and ICES-003. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communica-
tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1.

this device may not cause harmful interference, and

2.

this device must accept any interference received, including interference that may cause
undesired operation.

Содержание BlueJay M-2913

Страница 1: ...rum peer to peer point to point point to multipoint and master slave high speed 1 Mbps data transmission rates at ranges up to 1500 feet Interfaces with host computer running Windows 98 SE or later Substation hardened to withstand temperatures from 40 to 80 degrees C and humidity up to 95 ...

Страница 2: ...s not installed and used in accordance with the operating instructions it can cause harmful interference to communications If this equipment causes harmful interference to radio or television reception the user should try and correct the interference by Reorienting or relocating the receiving transmitting antenna Increasing the separation between the equipment and the M 2913 Connecting the equipme...

Страница 3: ...2 4 GHz ISM band The over the air data rate is TBD Mbps Transmit 1 Mbps Receive 1 Mbps The M 2913 BlueJay Wireless Data Transceiver is used with a laptop or desktop computer and if it is to be used within a metal enclosed structure a cable extension must be used and the antenna mounted externally Antennas must be oriented in the same plane and located in view of the corresponding transceiver Beckw...

Страница 4: ...tion to operate successfully the RTU cannot poll all units simultaneously Optimal Antenna Configuration A variety of antenna types can be used with the M 2913 The antennas available from Beckwith Electric are FCC qualified for use with our product Use of an antenna not supplied by Beckwith Electric could violate FCC licensing and result in fines to the user All antenna types currently offered are ...

Страница 5: ...s If you are experiencing difficulty communicating through the M 2913 s ensure that the antennas are In direct line of sight with each other Oriented vertically with respect to earth Within 1500 Ft You may be encountering interference from another source Some examples of interference are cell towers 2 4 GHz telephones WiFi access points or Bluetooth wireless devices If the interference cannot be c...

Страница 6: ...ceiver USB Cable Laptop Figure 9 Line of Site Orientation of Antennas Environmental Temperature Proper operation maintained from 40 C to 80 C Humidity Proper operation is maintained up to 95 relative humidity non condensing Environmental Protection The power supply printed circuit board is conformally coated to inhibit fungus growth Enclosure 1 16 Aluminum Physical Size 5 88 high with antenna 9 43...

Страница 7: ... 7 M 2913 BlueJay Wireless Data Transceiver Ma de in U S A WIRELESS M 2913 PWR TX RX BlueJay T M CO INC EL ECT RIC BECKWITH 5 52 4 51 2 75 1 46 1 06 Figure 10 Outline Dimensions ...

Страница 8: ...rence to radio or television reception the user should try and correct the interference by Reorienting or relocating the receiving transmitting antenna Increasing the separation between the equipment and the M 2913 Connecting the equipment into an outlet on a different circuit from the M 2913 If these do not correct the interference consult an experienced radio television technician for assistance...

Страница 9: ...y approved by Beckwith Electric Co may void the user s authority to operate the equipment U S Patent for the M 2913 BlueJay Wireless Data Transceiver is pending The M 2913 BlueJay Wireless Data Transceiver is covered by a five year warranty from the date of shipment Specification is subject to change without notice ...

Страница 10: ...LECTRIC CO INC 6190 118th Avenue North Largo Florida 33773 3724 U S A PHONE 727 544 2326 FAX 727 546 0121 E MAIL marketing beckwithelectric com WEBPAGE www beckwithelectric com 800 2913 SP 00 C 07 04 2003 Beckwith Electric Printed in U S A 8 26 03 ...

Отзывы: