Страница 1: ...Box EMS 8x DU User manual for showers with start stop mode and flow control Beckmann GmbH 2013 19 12 2013 Vidhaugen 114 7550 Hommelvik Tele 73979017 91795392 e post post tgelectronics no www tgelectronics no ...

Страница 2: ...e unauthorized changes repair or innovations of the product Furthermore the Beckmann GmbH is not liable for losses costs faults or consequential losses that may emerge by using this product The technical data correspond to the current conditions Misprints errors or changes reserved Beckmann GmbH Brandtstraße 1 33161 Hövelhof Fon 49 0 52 57 98 23 0 Fax 49 0 52 57 98 23 11 info beckmann gmbh de www ...

Страница 3: ...sh 8 5 Programming 9 5 1 Procedure 9 5 2 Counter editing 9 5 3 Adjusting operating parameters 9 5 4 Switch parameter 9 5 5 Parameter list EMS 8x DU 10 6 Other 12 6 1 Switching on 12 6 2 Factory default settings 12 6 3 Readout serial number 12 7 Technical data 12 List of figures Figure 1 Dimensions 5 Figure 2 Installation for Start Stop mode 6 Figure 3 Installation for flow control mode 6 Figure 4 ...

Страница 4: ...irments of the device or other values Use the device only under faultless conditions as well as due safety and risk conscious regarding the user manual Especially eliminate faults that may impair safety immediately Keep the user manual always on site of the device Pay attention additional to the user manual to the general valid legal and other obligatory rules such as accident prevention and envir...

Страница 5: ...ngs with a diameter of 6 mm at the back side It must be taken care that the case is mounted vertically because otherwise the functioning of the coin selector may be reduced The EMS 8x should be mounted at a solid wall in order to avoid heavy vibrations Page 5 Figure 1 Dimensions Vidhaugen 114 7550 Hommelvik Tele 73979017 91795392 e post post tgelectronics no www tgelectronics no ...

Страница 6: ...h must be separated from the power supply 3 2 1 Start Stop operation mode For Start Stop operation mode a button closer has to be connected the provided input In this mode the hot and cold water pipe are controlled by solenoid valves Additionally cold water can delivery free of charge by setting P29 3 2 2 Flow control operation mode For flow control operation mode the contact of the flow control u...

Страница 7: ...ed P26 the water delivery starts after pushing the button if not water delivery starts after the minimum insertion has been reached While the time runs down the decimal point is flashing and the displayed remaining time is decreased After the time has run out completely the display shows 0 and the delivery is stoped The water delivery can be interrupted at any time by pressing the Start Stop butto...

Страница 8: ...is operation mode the time starts with the delivery of hot water Once the delivery is interrupted the time is stopped Session time out P24 is also available in this mode see 4 2 for detailed description and examples 4 4 Automatic hygiene flush This function is used to automatically flush the lines The automatic hygiene flush is is activated when the unit has not been used for a specified time P27 ...

Страница 9: ...g sections the 3 types of parameters counter operating values and switches are described 5 2 Counter editing Counters are cash counters customer counters or hour meters There are erasable and non erasable counters The erasable counters can be erased by pressing the or button Some counters have a range higher than 999 As the display has only 3 digits the notation is segmented on values higher than ...

Страница 10: ...o 49 999 P07 EMS 82 Count token value If ON the token value P08 is added to the cash counter P01 and P02 Switch On Off P08 EMS 82 Token value Cash value of a single token Operat 0 01 to 599 99 P10 Operating hours 1 Operation Hours in hours and minutes Counter 0 to 99 999 59 P11 Operating hours 2 not erasable as P10 Counter 0 to 99 999 59 P20 EMS 81 Minimum insertion Specifies the amount of coins t...

Страница 11: ...g time in seconds 0 no flushing Operat 0 to 240 P29 Cold water delivery time Specifies the time of a free cold water delivery free of charge not in flow control mode 0 no cold water delivery Operat 0 to 600s P30 Test mode Test Mode of device can be started Switch Start Stop P31 In operation If OFF the device can be switched out of service in case of failure Switch On Off P32 Storage If ON the rema...

Страница 12: ...pears in the display 6 3 Readout serial number For service purposes or software updates it is important to know the serial number of the device The serial number is either visible on a sticker which is attached on the electronics or it can be readout by the software Press and hold the P key during power up of the machine then the 8 digit serial number will appear in couples from left to right The ...