Notes on information security

The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online,
are equipped with security functions that support the secure operation of plants, systems, machines and
networks. Despite the security functions, the creation, implementation and constant updating of a holistic
security concept for the operation are necessary to protect the respective plant, system, machine and
networks against cyber threats. The products sold by Beckhoff are only part of the overall security concept.
The customer is responsible for preventing unauthorized access by third parties to its equipment, systems,
machines and networks. The latter should be connected to the corporate network or the Internet only if
appropriate protective measures have been set up.

In addition, the recommendations from Beckhoff regarding appropriate protective measures should be
observed. Further information regarding information security and industrial security can be found in our

https://www.beckhoff.com/secguide

.

Beckhoff products and solutions undergo continuous further development. This also applies to security
functions. In light of this continuous further development, Beckhoff expressly recommends that the products
are kept up to date at all times and that updates are installed for the products once they have been made
available. Using outdated or unsupported product versions can increase the risk of cyber threats.

To stay informed about information security for Beckhoff products, subscribe to the RSS feed at 

https://

www.beckhoff.com/secinfo

.

Содержание TX1200

Страница 1: ...Manual EN TX1200 TwinCAT 2 PLC Library TcModbusTCPBC 2022 05 02 Version 1 0...

Страница 2: ......

Страница 3: ...1 Foreword 5 1 1 Notes on the documentation 5 1 2 Safety instructions 6 1 3 Notes on information security 7 2 Overview 8 3 Function blocks 9 3 1 FB_ModbusTcpOpen 9 3 2 FB_ModbusTcpClose 10 3 3 FB_Modb...

Страница 4: ...Table of contents TX1200 4 Version 1 0...

Страница 5: ...ve already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT G10 EtherCAT P...

Страница 6: ...familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions mus...

Страница 7: ...The latter should be connected to the corporate network or the Internet only if appropriate protective measures have been set up In addition the recommendations from Beckhoff regarding appropriate pr...

Страница 8: ...se of resources at a minimum If it is necessary to establish a further connection a connection that is not required must first be closed After about 10 seconds a connection that has not been used duri...

Страница 9: ...during that period is automatically closed and must be reopened if needed VAR_INPUT VAR_INPUT bStart BOOL sRemoteIPAddr STRING 15 tTimeOut TIME END_VAR bStart the function block is activated by a risi...

Страница 10: ...r in order to maintain the use of resources at a minimum If it is necessary to establish a further connection a connection that is not currently in use must first be closed A connection is automatical...

Страница 11: ...put has been reset iErrorId supplies the command specific error code table or the device specific error code 14 if the bError output is set Error Codes Description 0x8400 Connection is already closed...

Страница 12: ...passed here as a parameter The port number is generated afresh dynamically each time the connection is established with the FB_ModbusTcpOpen 9 function block pReqBuff contains the address of the buff...

Страница 13: ...x error Wrong protocol ID 0x8102 Rx error Wrong length 0x8103 Rx error Exceeding length 0x8104 Rx error Wrong unit ID Sample of calling the function block in FBD PROGRAM MAIN VAR fbModbusRequest FB_Mo...

Страница 14: ...Receive exceeding length 0x8104 Receive wrong unit ID Value hex Description Transmit Error 0x8300 Transmit timeout 0x8301 Transmit Shutdown 0x8302 Transmit internal error 0x8303 Transmit resource erro...

Страница 15: ......

Страница 16: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com tx1200...

Отзывы: