Technical data, mounting, wiring
PS3031-4820-0000
25
Version: 1.0
Shutdown input
Designation (G)
Description
Shutdown input
Input for shutdown and remote control
Enables the power supply to be switched off. Can be activated by a switch contact or external voltage. The
remote control input allows the output voltage to be set. For details see chapters
and
Selector switch for "Parallel Use" / "Single Use" mode
Designation (H)
Description
Selector switch for "Parallel
Use" / "Single Use" mode
Set the jumper to "Parallel Use" mode if power supplies are connected in parallel to increase the output
power. In order to distribute the load current between the individual power supplies, "Parallel Use" mode
regulates the output voltage so that the idle voltage is approx. 4% higher than at nominal load. See also
chapter
"Parallel Use" for power increase [
. A missing jumper corresponds to "Single Use" mode.
LED displays
Overload LED
DC-OK LED
DC-OK contact
Normal mode
OFF
ON
Closed
During extra power
OFF
ON
Closed
Overload (Vout < 90%)
ON
OFF
Open
Short circuit at output
ON
OFF
Open
Temperature switch-off
flashes
OFF
Open
Shutdown input active
flashes
OFF
Open
No input power
OFF
OFF
Open