background image

Documentation | EN

PS1061-2405-0000

Power supply 24 V DC, 5 A, 1 phase, AC 200-240 V

2021-06-16 | Version: 1.0

Содержание PS1061-2405-0000

Страница 1: ...Documentation EN PS1061 2405 0000 Power supply 24 V DC 5 A 1 phase AC 200 240 V 2021 06 16 Version 1 0...

Страница 2: ......

Страница 3: ...erminals and wiring 20 3 10 Functional wiring diagram 20 3 11 Front side and operating elements 21 3 12 EMC 22 3 13 Environment 23 3 14 Protective functions and safety features 24 3 15 Dielectric stre...

Страница 4: ...Table of contents PS1061 2405 0000 4 Version 1 0...

Страница 5: ...ee relay contact monitor the status of the output voltage Overview of technical data Overview of technical data PS1061 2405 0000 Output voltage 24 V DC Adjustment range 24 28 V 24 1 V preset Output cu...

Страница 6: ...d XPlanar are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could vi...

Страница 7: ...device is designed for installation in a housing and is intended for general professional use for example in industrial control systems or office communication and measuring equipment Do not use this...

Страница 8: ...n the device Provide protection against unintentional re connection Ensure proper wiring by following all local and national regulations Do not modify or attempt to repair the device Do not open the d...

Страница 9: ...e reduced from 5 mm to zero if the device is permanently loaded with less than 50 The device is designed tested and approved for branch circuits up to 20 A without an additional protective device Use...

Страница 10: ...minal voltage range may be provided with tolerances e g AC 230 V 10 The calculated total range then indicates the working range of the device Example DC 12 V refers to a 12 V battery regardless of whe...

Страница 11: ...quirements 8 Input current Typ 1 06 A At 24 V 5 A 230 Vac see fig Input to output current power factor to output current Power factor Typ 0 54 At 24 V 5 A 230 Vac see fig Input to output current power...

Страница 12: ...Technical data mounting wiring PS1061 2405 0000 12 Version 1 0 Fig 2 Input current over output current power factor over output current...

Страница 13: ...Technical data mounting wiring PS1061 2405 0000 13 Version 1 0 3 2 DC input Do not use the power supply unit with DC input voltages...

Страница 14: ...ring the first few microseconds after switching on is not taken into account AC 230 V Input inrush current Max 37 Apeak At 40 C cold start Typ 28 Apeak At 25 C cold start Typ 23 Apeak At 40 C cold sta...

Страница 15: ...typical Hiccup mode 1 Output voltage 2 10 Vdc depending on the input voltage see fig Output voltage to output current Short circuit current Max 9 8 A Continuous current see fig Output voltage to outpu...

Страница 16: ...ad Without load the hold up time can be several seconds The green DC OK lamp also lights up during this time 230 Vac Mains failure Hold up time Typ 69 ms At 24 V 2 5 A see Fig Hold up time over input...

Страница 17: ...ntact closes when the output voltage reaches 22 V The contact opens as soon as the output voltage falls below 22 V Switching hysteresis typ 0 7 V Contact load capacity Maximum 60 Vdc 0 3 A 30 Vdc 1 A...

Страница 18: ...W At 24 V 0 A Typ 7 0 W At 24 V 2 5 A Typ 12 6 W At 24 V 5 A The average efficiency is based on assumptions for a typical application with a power supply load of 25 of the nominal load for 25 of the t...

Страница 19: ...is stated in operating hours and is calculated according to the specifications of the capacitor manufacturer The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15...

Страница 20: ...0 a AWG 20 10 d 2 8 mm e AWG 24 16 f AWG 24 16 a AWG 24 16 d 1 6 mm Strip length 7 mm 0 28 inch 7 mm 0 28 inch 7 mm 0 28 inch e solid wire f stranded wire a with ferrule Wiring instructions Use suitab...

Страница 21: ...escription two identical positive poles positive output two identical negative poles negative output Potentiometer for the output voltage Designation C Description Potentiometer Guaranteed adjustment...

Страница 22: ...be used without additional measures to construct a local DC supply network The device is unsuitable for AC 200 V mains supplies and more than 4 5 A load current if a short drop in the output voltage...

Страница 23: ...Hz 1 6 mm 17 8 500 Hz 2 g 2 hours axis According to IEC 60068 2 6 Impacts3 30 g 6 ms 20 g 11 ms 3 impacts direction 18 impacts in total According to IEC 60068 2 27 Overvoltage category II According t...

Страница 24: ...er information see EMC 22 chapter Input fuse included Slow blow fuse not user replaceable with high braking power Safety features Insulation resistance Min 500 MOhm In the delivery state between input...

Страница 25: ...n the table below When checking the input to DC OK see the following figure B make sure that the maximum voltage between DC OK and the output is not exceeded see column D in the table below When perfo...

Страница 26: ...ls EU declaration of conformity UK Declaration of Conformity Trade conformity assessment for England Scotland and Wales The UKCA mark indicates conformity with the UK Statutory Instruments 2016 No 110...

Страница 27: ...ired DIN rail Use 35 mm DIN rails according to EN 60715 or EN 50022 with a height of 7 5 or 15 mm Weight 350 g Plastic material of the housing Flame retardant polycarbonate PC UL94 V0 Vicat softening...

Страница 28: ...s Such voltages must be protected with a touch guard Grounding of the output is required if the sum of the output voltage is more than 60 Vdc Avoid application of return voltage e g from a braking mot...

Страница 29: ...1 1 redundancy Be sure to use a redundancy module in order to decouple devices from one another This pre vents the defective device from becoming a load for the other device and the output voltage no...

Страница 30: ...rature inside the housing is considered the ambient temperature for the power supply The power supply is positioned at the center of the housing There are no other heat generating elements in the hous...

Страница 31: ...e secure and fast installation The redundancy module requires no additional auxiliary voltage Due to the international approvals package the device is suitable for virtually every application Observe...

Страница 32: ...or on the rear panel of the control cabinet protocol based communication with the Industrial PC either via OCT One Cable Technology or USB digital signals for communication with non protocol capable...

Страница 33: ...Appendix PS1061 2405 0000 33 Version 1 0 5 2 Documentation issue status Version Comment 1 0 First public issue 0 1 Provisional documentation for PS1061 2405 0000...

Страница 34: ...nts there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services sup...

Страница 35: ......

Страница 36: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com ps1061 2405 0000...