Wiring HD Terminals

The High Density Terminals of the KLx8xx and ELx8xx series doesn't support steady wiring.

Ultrasonically "bonded" (ultrasonically welded) conductors

Ultrasonically “bonded” conductors

It is also possible to connect the Standard and High Density terminals with ultrasonically
“bonded” (ultrasonically welded) conductors. In this case, please note the tables concerning the

wire-size width [

}

 16]

 below!

Wiring

Terminals for standard wiring ELxxxx/KLxxxx and for pluggable wiring ESxxxx/KSxxxx

Fig. 10: Mounting a cable on a terminal connection

Up to eight connections enable the connection of solid or finely stranded cables to the Bus Terminals. The
terminals are implemented in spring force technology. Connect the cables as follows:

1. Open a spring-loaded terminal by slightly pushing with a screwdriver or a rod into the square opening

above the terminal.

2. The wire can now be inserted into the round terminal opening without any force.

3. The terminal closes automatically when the pressure is released, holding the wire securely and per-

manently.

Terminal housing

ELxxxx, KLxxxx

ESxxxx, KSxxxx

Wire size width

0.08 ... 2,5 mm

2

0.08 ... 2.5 mm

2

Wire stripping length

8 ... 9 mm

9 ... 10 mm

High Density Terminals ELx8xx, KLx8xx (HD)

The conductors of the HD Terminals are connected without tools for single-wire conductors using the direct
plug-in technique, i.e. after stripping the wire is simply plugged into the contact point. The cables are
released, as usual, using the contact release with the aid of a screwdriver. See the following table for the
suitable wire size width.

Содержание KL2798

Страница 1: ...Documentation EN KL2798 Bus terminal 8 channel solid state output 30 V AC 48 V DC 2 A potential free 2021 06 17 Version 1 1 0...

Страница 2: ......

Страница 3: ...Documentation Issue Status 7 2 Product overview 8 2 1 Introduction 8 2 2 Technical data 9 3 Presentation KL2798 within TwinCAT 10 4 Mounting and wiring 11 4 1 Instructions for ESD protection 11 4 2 I...

Страница 4: ...Table of contents KL2798 4 Version 1 1 0...

Страница 5: ...oducts that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT...

Страница 6: ...ained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructions are u...

Страница 7: ...ion Version KL2798 0000 Firmware Hardware 1 1 0 01 1 0 0 00 The firmware and hardware versions delivery state can be taken from the serial number printed on the side of the terminal Syntax of the seri...

Страница 8: ...through high performance MOSFET transistors with low switch on resistance The switch itself is not short circuit proof but due to its high pulse current capability it can cope with current until an ex...

Страница 9: ...ed typ 30 ms max 50 ms On resistance typ 0 03 Current consumption power contacts Current consumption K bus 80 mA Bit width in the process image 8 output bits Special features substitute for relay cont...

Страница 10: ...Presentation KL2798 within TwinCAT KL2798 10 Version 1 1 0 3 Presentation KL2798 within TwinCAT Fig 2 KL2798 within TwinCAT 2 11...

Страница 11: ...ure you are electrostatically discharged and avoid touching the contacts of the device directly Avoid contact with highly insulating materials synthetic fibers plastic film etc Surroundings working pl...

Страница 12: ...coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the terminals are clipped onto the mounting rail fi...

Страница 13: ...ents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics and...

Страница 14: ...least 10 mm from the group of terminals WARNING Risk of electric shock The PE power contact must not be used for other potentials 4 3 Connection system WARNING Risk of electric shock and damage of dev...

Страница 15: ...risk of wires being mixed up The familiar dimensions of the terminal only had to be changed slightly The new connector adds about 3 mm The maximum height of the terminal remains unchanged A tab for s...

Страница 16: ...inals are implemented in spring force technology Connect the cables as follows 1 Open a spring loaded terminal by slightly pushing with a screwdriver or a rod into the square opening above the termina...

Страница 17: ...eve 0 14 0 75 mm2 Wire size width single core wires 0 08 1 5 mm2 Wire size width fine wire conductors 0 25 1 5 mm2 Wire size width ultrasonically bonded conductors only 1 5 mm2 see notice 16 Wire stri...

Страница 18: ...ut 3 Output 4 4 Output 4 Output 5 5 Output 5 Output 6 6 Output 6 Output 7 7 Output 7 Output 8 8 Output 8 Output 1 9 Output 1 Output 2 10 Output 2 Output 3 11 Output 3 Output 4 12 Output 4 Output 5 13...

Страница 19: ...ents there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services su...

Страница 20: ...within TwinCAT 2 11 10 Fig 3 Spring contacts of the Beckhoff I O components 11 Fig 4 Attaching on mounting rail 12 Fig 5 Disassembling of terminal 13 Fig 6 Power contact on left side 14 Fig 7 Standard...

Страница 21: ......

Страница 22: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com KL2798...

Отзывы: