Beckhoff KL2784 Скачать руководство пользователя страница 5

Foreword

KL2784 und KL2794

5

Version: 2.0.0

1

Foreword

1.1

Notes on the documentation

Intended audience

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the documentation and the following notes and explanations are followed when installing
and commissioning these components.
It is the duty of the technical personnel to use the documentation published at the respective time of each
installation and commissioning.

The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development.

We reserve the right to revise and change the documentation at any time and without prior announcement.

No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.

Trademarks

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 are registered

trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patent Pending

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or
registrations in various other countries.

The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.

EtherCAT

®

 is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,

Germany

Copyright

© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.

Содержание KL2784

Страница 1: ...Documentation KL2784 und KL2794 Four channel digital output terminals with MOSFET transistors 2 0 0 2017 08 08 Version Date...

Страница 2: ......

Страница 3: ...w 8 2 1 KL2784 Introduction 8 2 2 KL2794 Introduction 9 2 3 Technical data 10 2 4 LEDs 11 3 Mounting and wiring 12 3 1 Installation on mounting rails 12 3 2 Connection 15 3 2 1 Connection system 15 3...

Страница 4: ...Table of contents KL2784 und KL2794 4 Version 2 0 0...

Страница 5: ...of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automa...

Страница 6: ...re familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions m...

Страница 7: ...0 02 02 1 0 0 02 02 The K bus firmware and hardware version delivery state are indicated by the serial number printed at the side of the terminal Syntax of the serial number Structure of the serial n...

Страница 8: ...or switches connected to the power contacts represent a substitute for relay contacts They are short circuit proof and free from wear thereby increasing the availability of the application The output...

Страница 9: ...four potential free semiconductor switches represent a substitute for relay contacts They are short circuit proof and free from wear thereby increasing the availability of the application The output i...

Страница 10: ...consumption from K bus typically 80 mA Bit width in the output process image 4 bit Configuration via the Bus Coupler or the controller Weight approx 50 g Permissible ambient temperature range during o...

Страница 11: ...EDs LED Display Signal LED 1 off Output 1 switched off on Output 1 switched on Signal LED 2 off Output 2 switched off on Output 2 switched on Signal LED 3 off Output 3 switched off on Output 3 switche...

Страница 12: ...the Fieldbus Coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the Terminals are clipped onto the mou...

Страница 13: ...ponents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics a...

Страница 14: ...ation testing or to damage on the terminal e g disruptive discharge to the PE line during insulation testing of a consumer with a nominal voltage of 230 V For insulation testing disconnect the PE supp...

Страница 15: ...sity Standard wiring ELxxxx KLxxxx Fig 7 Standard wiring The terminals of ELxxxx and KLxxxx series have been tried and tested for years They feature integrated screwless spring force technology for fa...

Страница 16: ...Terminals from these series with 16 terminal points are distinguished by a particularly compact design as the packaging density is twice as large as that of the standard 12 mm Bus Terminals Massive c...

Страница 17: ...y don t toggle 2 The wire can now be inserted into the round terminal opening without any force 3 The terminal point closes automatically when the pressure is released holding the wire securely and pe...

Страница 18: ...and damage to the device Bring the Bus Terminals system into a safe de energized state before starting mounting disassembly or wiring of the Bus Terminals Fig 11 KL2784 Connection Terminal point No C...

Страница 19: ...ssembly or wiring of the Bus Terminals Fig 12 KL2794 Connection Terminal point No Connection for Output 1 1 Output 1 Potential free contact Output 1 2 Output 1 Potential free contact Output 3 3 Output...

Страница 20: ...ct against the rated operating voltage being exceeded by more than 40 due to short term interference voltages The individual terminals may only be unplugged or removed from the Bus Terminal sys tem if...

Страница 21: ...on of the Beckhoff terminal systems in potentially explo sive areas ATEX Pay also attention to the continuative documentation Notes about operation of the Beckhoff terminal systems in potentially expl...

Страница 22: ...ckhoff components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support S...

Страница 23: ...Fig 3 LEDs 11 Fig 4 Attaching on mounting rail 12 Fig 5 Disassembling of terminal 13 Fig 6 Power contact on left side 14 Fig 7 Standard wiring 15 Fig 8 Pluggable wiring 15 Fig 9 High Density Terminals...