TwinCAT configuration
FC1028
23
Version: 1.0
1. Activate the distributed clocks for all EtherCAT masters that you want to synchronize with each other
2. Activate a reference clock for each of these EtherCAT masters.
3. Click at the first EtherCAT master on the left side in the tree view on the EtherCAT master and then
under the
EtherCAT
tab on the button
Advanced Settings
.
4. Deactivate the
Automatic DC Mode Selection
option.
5. Activate the option
DC in use
in
Distributed Clocks
and additionally the option
DC Time controlled by
CCAT Time (Master Mode)
All following EtherCAT masters are synchronized with this EtherCAT master.