Mounting and Wiring
EL600x, EL602x
41
Version: 4.6
4.2.4
LEDs and terminal connector assignments
LEDs
Fig. 30: EL6001, EL6021 - LEDs and Connection
LED
Color
Meaning
RUN
Green
This LED indicates the terminal's operating state:
Off
: INIT = initialization of the
terminal or BOOTSTRAP = function for
of the
terminal
flashing
State of the EtherCAT state machine: PREOP = function for mailbox
communication and variant standard settings
Single flash State of the EtherCAT state machine: SAFEOP = verification of the
channels and the distributed clocks.
Outputs remain in safe state
On
State of the EtherCAT State Machine: OP = normal operating state;
mailbox and process data communication is possible
TxD
Green
State of the transmit signal line (on: HI signal level on transmit line)
RxD
Green
State of the receive signal line (on: HI signal level on receive line)