Commissioning/Configuration
EP4174-0002
57
Version: 1.1.0
Index F008 Code word
Index (hex) Name
Meaning
Data type
Flags
Default
F008:0
Code word
UINT32
RW
0x00000000
(0
dec
)
Index F010 Module list
Index (hex) Name
Meaning
Data type
Flags
Default
F010:0
Module list
UINT8
RW
0x04 (4
dec
)
F010:01
SubIndex 001
UINT32
RW
0x00000190
(400
dec
)
F010:02
SubIndex 002
UINT32
RW
0x00000190
(400
dec
)
F010:03
SubIndex 003
UINT32
RW
0x00000190
(400
dec
)
F010:04
SubIndex 004
UINT32
RW
0x00000190
(400
dec
)
4.5
Restoring the delivery state
To restore the delivery state for backup objects in ELxxxx terminals / EPxxxx boxes, the CoE object
Restore
default parameters, SubIndex 001
can be selected in the TwinCAT System Manager (Config mode).
Fig. 44: Selecting the Restore default parameters PDO
Double-click on
SubIndex 001
to enter the Set Value dialog. Enter the value
1684107116
in field
Dec
or the
value
0x64616F6C
in field
Hex
and confirm with OK.
All backup objects are reset to the delivery state.