Commissioning
EL72x1-901x
119
Version: 1.9
Fig. 146: Automatic linking of all main variables
• Several parameters have to be set before the motor can be started up. The values can be found in
sections "
Please set these parameters before continuing with the motor commissioning procedure.
5.3.2
Settings with the Drive Manager
(Master TwinCAT 2.11 R3)
The data given here serve as an example for a servomotor type AM8131-0F20-0000 from Beckhoff
Automation. For other motors the values may vary, depending on the application.
Using the Drive Manager from revision -0019
The Drive Manager is only supported from revision -0019 of the EL72x1-xxxx. If you use an older
version, the settings have to be made manually. See chapters "
tings"
Table of contents
• Start-up with the Drive Manager [
• Setting further parameters with the Drive Manager [
- Integral velocity controller component Tn [
- Proportional velocity controller component Kp [
The TwinCAT Drive Manager is available for
download in the AX5000 download package
.
The TwinCAT Drive Manager for parameterizing an EL72x1-xxxx servo terminal is integrated in the System
Manager, so that no separate configuration tool is required. Once a servo terminal has been detected or
entered, the TwinCAT Drive Manager is available in the Configuration tab.
The following instructions are intended to enable you to start up the servo terminal relatively quickly. More
detailed information on the Drive Manager can be found in the corresponding documentation "
Содержание EL72 1-901 Series
Страница 1: ...Documentation EL72x1 901x Servo Motor Terminals with OCT and STO 50 V DC 1 9 2020 02 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Страница 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Страница 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Страница 86: ...Commissioning EL72x1 901x 86 Version 1 9 Fig 88 Incorrect driver settings for the Ethernet port...
Страница 140: ...Commissioning EL72x1 901x 140 Version 1 9 0hex 80hex Fault reset 6hex Shutdown 7hex Switch on Fhex Enable operation...
Страница 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Страница 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Страница 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Страница 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...