Operation
EK1960
65
Version: 1.3.1
4.3.3.11
TwinSAFE groups
It makes sense to create TwinSAFE groups in cases where different machine safety zones are to realize, or
simply in order to separate the fault behavior. Within a group, a FB or connection error (here: alias device)
leads to a group error and therefore to switching off all outputs for this group. If an error output of an FB is
set, it will be forwarded as a logical 1 signal.
A group can be created by opening the context menu of the safety project and selecting
Add
and
New
Item...
.
Fig. 61: Creating a TwinSAFE group
Like the first group, the group of a subitem for the alias devices and a sal worksheet.
Fig. 62: Components of the TwinSAFE group
The instance path to the FB port to be linked can be specified, in order to exchange signals between the
groups. The instance path consists of the group name, the FB name and the FB port, each separated by a
dot. The input of the instance path is case-sensitive.
<group name>.<network name>.<FB name>.<FB port name>
Sample: TwinSafeGroup1.Network1.FBEstop1.EStopIn3
Alternatively,
Change Link
can be selected by opening the context menus next to the FB port.
Содержание EK1960 Series
Страница 1: ...Operating Instructions for EK1960 TwinSAFE Compact Controller 1 3 1 2019 01 28 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EK1960 6 Version 1 3 1...
Страница 58: ...Operation EK1960 58 Version 1 3 1 Fig 51 Safety parameters of the input modules...
Страница 102: ...Operation EK1960 102 Version 1 3 1 Fig 131 Group Status Online ERROR Fig 132 Group Status Online STOP...
Страница 140: ...Appendix EK1960 140 Version 1 3 1 5 2 Certificates...