Index 8010 SSI Settings
Index
(hex)
Name
Meaning
Data type
Flags Default
8010:0
SSI settings
Length of this object
UINT8
RO
0x13 (19
dec
)
8010:01
Disable frame error
0: Frame error is not suppressed
1: Frame error is suppressed
BOOLEAN
RW
0x00 (0
dec
)
8010:02
Enable power failure bit 0: Power failure bit is not active
1: Power failure bit is active: the last bit of the data frame
(encoder-specific error bit) is shown as an error bit in ob-
ject
and bit 2 of the status word.
BOOLEAN
RW
0x00 (0
dec
)
8010:03
Enable inhibit time
0: Inhibit time is not active
1: Inhibit time is active
BOOLEAN
RW
0x00 (0
dec
)
8010:04
Enable test mode
0: Test mode is not active
1: Test mode is active
BOOLEAN
RW
0x00 (0
dec
)
8010:06
SSI coding
0: Binary code active
1: Gray code active
BIT1
RW
0x01 (1
dec
)
8010:09
SSI baud rate
0: reserved
1: 1250 kbaud
2: 1000 kbaud
3: 500 kbaud
4: 250 kbaud
5: 125 kbaud
6 - 65535: reserved
BIT3
RW
0x03 (3
dec
)
8010:0F
SSI-frame type
0: Multi-turn analysis is active (25 bit data frame)
1: Single-turn-analysis is active (13 bit data frame)
2: Variable analysis is active. The length of the data
frame (1 to 32 bit) is specified via object 0x8010:11.
BIT2
RW
0x00 (0
dec
)
8010:11
SSI frame size
Length of the SSI data frame (in bits)
UINT16
RW
0x0019 (25
dec
)
8010:12
SSI data length
Data length
UINT16
RW
0x0018 (24
dec
)
8010:13
Min. inhibit time[µs]
Minimum inhibit time in µs (1 to 65535)
UINT16
RW
0x0000 (0
dec
)
6.2.3
Input data
Index 6000 SSI Inputs
Index
(hex)
Name
Meaning
Data type
Flags Default
6000:0
SSI Inputs
Length of this object
UINT8
RO
0x11 (17
dec
)
6000:01
Data error
SSI input error:
• SSI without power supply
• Broken wire at SSI data inputs D+ or D-
• Data cables interchanged
• If no data transfer takes place the SSI input of the
terminal is on low level.
BOOLEAN
RO
0x00 (0
dec
)
6000:02
Frame error
The data frame is wrong, i.e. the data frame was not ter-
minated with zero (perhaps wire breakage on clock ca-
bles)
BOOLEAN
RO
0x00 (0
dec
)
6000:03
Power failure
An encoder-specific error has occurred. This error bit is
only displayed if it was activated beforehand by index
.
BOOLEAN
RO
0x00 (0
dec
)
6000:0E
Sync error
The Sync Error bit is only required for the DC mode. It in-
dicates whether a synchronization error occurred in the
expired cycle.
This means a SYNC signal was triggered in the EL5002,
although no new process data were available (0=OK,
1=NOK).
BOOLEAN
RO
0x00 (0
dec
)
6000:0F
TxPDO State
Validity of the data of the associated TxPDO (0 = valid, 1
= invalid).
BOOLEAN
RO
0x00 (0
dec
)
6000:10
TxPDO Toggle
The TxPDO toggle is toggled by the slave when the data
of the associated TxPDO is updated.
BOOLEAN
RO
0x00 (0
dec
)
6000:11
Counter value
Counter value
UINT32
RO
0x00000000 (0
dec
)