Ethernet X001 Interface
CX8095
71
Version: 1.5
8.4
ADS-Communication
Communication
The ADS protocol (ADS: Automation Device Specification) is a transport layer within the TwinCAT system. It
was developed for data exchange between the different software modules, for instance the communication
between the NC and the PLC. This protocol enables communication with other tools from any point within
the TwinCAT. If communication with other PCs or devices is required, the ADS protocol can use TCP/IP as a
basis. Within a networked system it is thus possible to reach all data from any point.
The ADS protocol runs on top of the TCP/IP or UDP/IP protocols. It allows the user within the Beckhoff
system to use almost any connecting route to communicate with all the connected devices and to
parameterize them. Outside the Beckhoff system a variety of methods are available to exchange data with
other software tools.
Software interfaces
ADS-OCX
The ADS-OCX is an Active-X component. It offers a standard interface to, for instance, Visual Basic, Delphi,
etc.
ADS-DLL
You can link the ADS-DLL (DLL: Dynamic Link Library) into your C program.
OPC
The OPC interface is a standardized interface for communication used in automation engineering. Beckhoff
offer an OPC server for this purpose.
Protocol
The ADS functions provide a method for accessing the Bus Coupler information directly from the PC. ADS
function blocks can be used in TwinCAT PLC Control for this. The function blocks are contained in the
PLCSystem.lib
library. It is also equally possible to call the ADS functions from AdsOCX, ADSDLL or OPC.
Содержание CX8095
Страница 1: ...Manual CX8095 Embedded PC with EtherNet IP Interface 1 5 2018 02 09 Version Date...
Страница 2: ......
Страница 56: ...Parameterization and commissioning CX8095 56 Version 1 5 1 Create a new controller 2 Append a new module...
Страница 65: ...Ethernet X001 Interface CX8095 65 Version 1 5 8 1 2 Topology example CX8095...
Страница 76: ...Error handling and diagnosis CX8095 76 Version 1 5...