background image

Manual  | EN

CX2500-0070

USB 3.0 Module

2/10/2021 | Version: 1.1

Содержание CX2500-0070

Страница 1: ...Manual EN CX2500 0070 USB 3 0 Module 2 10 2021 Version 1 1...

Страница 2: ......

Страница 3: ...unting and wiring 10 3 1 Unpacking installation and transport 10 3 2 Dimensions 11 3 3 Attaching the system interface to the CX20x0 system 12 3 4 Installation on the mounting rail 12 3 5 Mounting the...

Страница 4: ...Table of contents CX2500 0070 4 Version 1 1...

Страница 5: ...ucts that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT G EtherCAT G10 EtherCAT P Safety...

Страница 6: ...are familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions...

Страница 7: ...Foreword CX2500 0070 7 Version 1 1 1 3 Documentation issue state Version Changes 1 1 notes on max power supply for the ports changed 1 0 updated Version 0 1 first Version...

Страница 8: ...s e g during a function test To disconnect first pull the first terminal behind the power supply unit optional then pull the connectors of the fieldbus connections System components that have been swi...

Страница 9: ...the CX2000 family are connected to the CPU on the right hand side via a multi pin connector Up to two CX2550 0010 CFast modules can be connected so that a total of up to three CFast slots are availab...

Страница 10: ...shipping damage 6 If you notice any shipping damage or inconsistencies between the contents and your order you should notify Beckhoff Service NOTE Danger of damage to the device During transport in co...

Страница 11: ...Mounting and wiring CX2500 0070 11 Version 1 1 3 2 Dimensions The following drawings show the dimensions of the CX2500 0070 interface Dimensions...

Страница 12: ...s into place Further modules can be connected to the system in the same way Once all modules are connected the system is placed on the DIN rail as a block For details please refer to the section on DI...

Страница 13: ...ages below show the permitted and two incorrect installation positions Mounting must provide a clearance of 30 mm both above and below a CX20x0 device combination to ensure adequate ventilation of the...

Страница 14: ...X20x0 system must not be operated vertically on the DIN rail A vertical position would lead to insufficient CPU ventilation since the ventilation openings are located on the top and bottom of the hous...

Страница 15: ...rule the latching of the modules to each other is sufficiently strong However it is possible for the controller and its modules to be exposed to vibrations shocks or impacts The modules can be securel...

Страница 16: ...In order to dismantle the assembly it must first be removed from the support rail Afterwards the bar clips can be removed with the aid of a screwdriver Once the bar clips have been raised they can be...

Страница 17: ...lies with the USB 3 0 specification Pin Assignment Description 1 VBus 5V Power 2 USB D USB 2 0 data 3 USB D 4 GND Ground 5 StdA_SSRX SuperSpeed receiver 6 StdA_SSRX SuperSpeed receiver 7 GND_DRAIN Sig...

Страница 18: ...es regarding the cables used In order to ensure trouble free operation only cables that comply with the USB 3 0 specification should be used If the interface is operated in compatibility mode for USB...

Страница 19: ...e PC for the first time the pre installed operating system optional will be started Switching off The Embedded PC switches off when the power supply unit is switched off The control software typically...

Страница 20: ...ause of the fault is either in the software or in parts of the plant outside the Embedded PC Call the manufacturer of the machine or the software CF card access error Faulty CFast card faulty CFast sl...

Страница 21: ...rom the DIN rail Proceed as follows 2 1 Release and remove the first Terminal next to the power supply unit on the DIN rail First remove any wiring from power supply unit and then from the first termi...

Страница 22: ...national electronics scrap regulations 3 Disconnecting the system interface Disconnecting the system modules from the basic module If the modules are locked i e attached with tie clips the clips must...

Страница 23: ...of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and ca...

Страница 24: ...ponents there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support off...

Страница 25: ......

Страница 26: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com CX2500 0070...

Отзывы: