Содержание CU8880-0010

Страница 1: ...Installation and Operating instructions for CU8880 0010 Ethernet Controller with USB Input Version 1 4 Date 2018 04 12 ...

Страница 2: ......

Страница 3: ... standard CAT5 cable 5 LED Diagnostics 6 Installation Instructions 7 Transport and Unpacking 7 Transport 7 Unpacking 7 Mounting Unmounting 8 Connecting devices 9 Connecting cables 9 Operating Instructions 10 Configuration 10 Appendix 11 Assembly dimensions 11 Service and Support 12 Beckhoff s branch offices and representatives 12 Beckhoff headquarters 12 Beckhoff Support 12 Beckhoff Service 12 Tec...

Страница 4: ...winSAFE and XFC are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners Patent Pending The EtherCAT Technology is covered including but not limited to the following patent applications and patents EP1590927 EP1789857 DE102004044764 DE1...

Страница 5: ...to alert the reader to the associated safety instructions Danger This symbol is intended to highlight risks for the life or health of personnel Warning This symbol is intended to highlight risks for equipment materials or the environment i Note This symbol indicates information that contributes to better understanding CU8880 0010 3 ...

Страница 6: ...e Ethernet interfaces can be implemented depending on the system configuration The CU8880 0010 is used for necessary IT communication so that the respective on board Ethernet interfaces are available for EtherCAT or real time Ethernet communication user friendly installation via integrated top hat rail adapter power supply via USB no supply voltage necessary compact industrial design clear quick d...

Страница 7: ...ctor The LED P20 lights green when power supply is connected Data connectors The connector are 1 USB port Type B and a RJ45 connector The pins are described below USB type B Port X20 standard cable USB type B Port Pin Signal 1 VCC 2 Data 3 Data 4 GND shield shield RJ 45 Port X10 standard CAT5 cable RJ 45 Port Pin Signal 1 TX 2 TX 3 RX 4 n c 5 n c 6 RX 7 n c 8 n c CU8880 0010 5 ...

Страница 8: ...us Meaning off no power supply connected P20 power supply lights green 5 VDC via USB Port off P10 Ethernet port lights green Ethernet Collision off P11 Ethernet port lights yellow Ethernet full duplex off P12 Ethernet port lights Ethernet Link off Ethernet Speed 10MBit P13 Ethernet port lights Ethernet Speed 100MBit 6 CU8880 0010 ...

Страница 9: ...emperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours must be allowed before the unit is switched on Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not discard the original packaging Keep it for fu...

Страница 10: ...the Ethernet Controller Just push the unit on the upper side under the rail figure 1 and snap in the lower side as shown below figure 2 Unmounting the Ethernet Controller To release the CU8880 0010 from the mounting rail pull down the locking clip with a screwdriver figure 1 and pull off the device from the rail figure 2 8 CU8880 0010 ...

Страница 11: ...handle it at the plug Do not pull the cable Connecting cables The connections are documented in the section Product Description When connecting the cables to the CU8880 0010 proceed according to the following sequence Switch off all the devices that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the CU8880 0010 and to th...

Страница 12: ...Operating Instructions Operating Instructions Configuration i Note The provided CD contains the according configuration software 10 CU8880 0010 ...

Страница 13: ...mall overall installed size With a height of approx 100 mm the module dimensions exactly match those of the Beckhoff Bus Terminals Together with the lowered connector surfaces this means that it can be used in a standard terminal box with a height of 120 mm CU8880 0010 11 ...

Страница 14: ... 20 D 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support offers you comprehensive technical assistance helping you no only with the application of individual Beckhoff products but also with other wide ranging services world wide support design programming and commissioning of complex automation systems and extensive training program for...

Страница 15: ...y on 35 mm mounting rail conforms to EN 50022 Installation position any Approvals CE Approvals for USA and Canada FCC Federal Communications Commission Radio Frequency Interference Statement FCC Approval for USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protect...