2.3   Compact-Flash card 

The Compact-Flash card (CFast card) is a non-volatile memory media. Data to be retained in the event of a power 
failure should be saved on the CFast card. The CFast card operates similar to a hard disk. 

Only use CFast cards that are made for industrial use 

 

Note 

It is recommended only use CFast cards that are made for industrial use. They 
possess a higher number of read / write cycles and an enhance temperature range (up 
to + 85°C). 
A proper operation of the device can only be guaranteed with the use of CFast cards 
from Beckhoff Automation GmbH! 

 

2.3.1  Inserting the CFast Card 

The CFast card must be inserted carefully upright with the written side to the left in the CFast slot. The 
slot has a protection to ensure the right inserting direction. The card can only be inserted wrong direction 
with violence. 

 

As soon as the card is inserted, the LED (

P20

) lights up green. The red LED (

P21

) flashes up shortly, too. 

2.3.2  Ejecting the CFast Card 

For ejecting press on the CFast card.The card now can be removed from the slot. The green LED (

P20

goes off when the card is removed. 
 
 

8

 

CU8871-0000 

Содержание CU8871-0000

Страница 1: ...Installation and Operating instructions for CU8871 0000 CFast card adapter with USB connector Version 1 2 Date 2019 03 18...

Страница 2: ......

Страница 3: ...r Supply 6 2 2 2 USB 3 0 type B Port X10 Standard Cable 7 2 2 3 CFast card slot X20 Standard CFast Interface 7 2 3 Compact Flash card 8 2 3 1 Inserting the CFast Card 8 2 3 2 Ejecting the CFast Card 8...

Страница 4: ...pendix 16 7 1 Beckhoff Support and Service 16 7 1 1 Beckhoff branches and partner companies 16 7 1 2 Beckhoff company headquarters 16 7 2 Approvals for USA and Canada 17 7 3 FCC Approval for USA 17 7...

Страница 5: ...S are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate th...

Страница 6: ...rd to materials and environment Note or pointer Note This symbol indicates information that contributes to better understanding 1 3 Operator s obligation to exercise diligence The operator must ensure...

Страница 7: ...e USB 3 0 connection offers the highest data transfer rate possible with a CFast card but the CFast card adapter can also be connected to PCs with a USB 2 0 interface Power is also supplied via USB St...

Страница 8: ...r supply is connected 2 2 1 1 Power consumption The power consumption of the device depends on the media plugged in the reader The table shows the values Media State Current consumption Power consumpt...

Страница 9: ...OT1 4 D04 I O I1Z 0Z3 21 D00 I O I1Z OZ3 38 Vcc Power 5 D06 I O I1Z 0Z3 22 D01 I O I1Z OZ3 39 CSEL I I2Z 6 D07 I O I1Z 0Z3 23 D02 I O I1Z OZ3 40 VS2 O Open 7 CE1 I I3U 24 WP O OT3 41 RESET I I2Z 8 A10...

Страница 10: ...p to 85 C A proper operation of the device can only be guaranteed with the use of CFast cards from Beckhoff Automation GmbH 2 3 1 Inserting the CFast Card The CFast card must be inserted carefully upr...

Страница 11: ...condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours mu...

Страница 12: ...71 0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022 To release the CU8871 0000 from the mounting rail 1 first pull the lug at the bottom of the hub downwards by using a screw driver...

Страница 13: ...ing the cables to the CU8871 0000 proceed according to the following sequence Switch off all the devices that are to be connected Disconnect all the devices that are to be connected from the power sup...

Страница 14: ...SB 3 0 suitable wire 4 2 LED Diagnosis LED Mapping Status Meaning off no power supply connected see chapter Power Supply for details P10 Power supply lights green device is operational off no CFast ca...

Страница 15: ...0000 USB CFast adapter is maintenance free 4 4 Shutting down 4 4 1 Disposal Observe national electronics scrap regulations Note Observe the national electronics scrap regulations when disposing of th...

Страница 16: ...overall installed size With a height of 100 mm the module dimensions exactly match those of the Beckhoff Bus Terminals Together with the lowered connector surfaces this means that it can be used in a...

Страница 17: ...details see chapter Power Supply Dimensions W x H x D app 34 mm x 100 mm x 76 mm with lug for mounting rail release Weight app 95 g Permissible ambient temperature 0 C to 55 C operation 25 C to 70 C t...

Страница 18: ...KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assista...

Страница 19: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a...

Отзывы: