background image

 

 
Installation- and Operating instructions for 

CU8803-0000 

CP-Link 4 transmitter box – The One Cable Display Link 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Version: 1.2 
Date: 2018-11-13 

Содержание CU8803-0000

Страница 1: ...Installation and Operating instructions for CU8803 0000 CP Link 4 transmitter box The One Cable Display Link Version 1 2 Date 2018 11 13 ...

Страница 2: ......

Страница 3: ...w 5 2 2 Connections 6 2 2 1 Power Supply X40 6 2 2 2 USB Input X10 6 2 2 3 DVI Input X20 7 2 2 4 CP Link 4 Output X30 7 2 3 LED Diagnostics 8 3 Installation 9 3 1 Transport and Unpacking 9 3 1 1 Transport 9 3 1 2 Unpacking 9 3 2 Mounting Demounting 10 3 3 Connecting devices 11 3 3 1 Connecting cables 11 3 3 2 Connecting Power Supply 11 4 Operation 12 4 1 CP Link 4 Architecture Description 12 4 2 M...

Страница 4: ...ckhoff Support and Service 16 7 1 1 Beckhoff branches and partner companies 16 7 1 2 Beckhoff company headquarters 16 7 2 Approvals for USA and Canada 17 7 3 FCC Approval for USA 17 7 4 FCC Approval for Canada 17 2 CU8803 0000 ...

Страница 5: ...and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners 1 1 3 Patent Pending The EtherCAT Technology is covered including but not limited to the following patent applications and patents EP1590927 EP1789857 DE102004044764 DE102...

Страница 6: ...ard to materials and environment Note or pointer Note This symbol indicates information that contributes to better understanding 1 3 Operator s obligation to exercise diligence The operator must ensure that the product is only used as intended see chapter Product Description the product is in a sound condition and in working order during operation see chapter Maintenance the product is operated ma...

Страница 7: ...ink 4 The power supply socket of the panel is not used Other outstanding features are 1 USB input with USB B socket to be connected to the PC in 1 m distance 1 DVI input with DVI D socket to be connected to the PC in 1 m distance 1 CP Link 4 output with RJ45 socket for up to 100 m Cat 6A cable for connecting a Control Panel with CP Link 4 interface CP29xx 0010 or CP39xx 0010 Power supply of the Co...

Страница 8: ...in assignment is shown at the imprint beside the connector The low resistance protective earthing connection is established via the ground pin Malfunction possible with missing ground connection Note A proper ground connection of the device is absolutely necessary for the correct function of the touchscreen 2 2 2 USB Input X10 X10 Connector USB TYP B LP mount WS The CP Link 4 transmitter box CU880...

Страница 9: ...ata 1 21 n c 10 TMDS Data 1 22 TMDS Clock shield 11 TMDS Data1 3 shield 23 TMDS Clock 12 n c 24 TMDS Clock 2 2 4 CP Link 4 Output X30 X30 BA 1x8pole RJ45 Invers shield 2XLWL Lp mount Molex Nr 43860 0016 Modular Jack The CP Link 4 transmitter box CU8803 0000 is connected with the Control Panel via the CP Link 4 output X30 Pin Signal Pin Signal 1 CP Link4_0P 5 CP Link4_2N 2 CP Link4_0N 6 CP Link4_1N...

Страница 10: ...ning off no power supply P10 Power supply lights green 24 VDC connected off no connection to the Control Panel P20 Connection lights green connection to the Control Panel established off no image data transmission P30 Activity flashes yellow DVI data transmission 8 CU8803 0000 ...

Страница 11: ...e condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours must be allowed before the unit is switched on 3 1 2 Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not discard the original packaging Keep it for future relocation 3 Check the...

Страница 12: ...k 4 transmitter box CU8803 0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022 To release the CP Link 4 transmitter box CU8803 0000 from the mounting rail press the device downwards till you can remove it from the rail 10 CU8803 0000 ...

Страница 13: ... be switched off before disconnecting the CP Link 4 output connection 3 3 1 Connecting cables The connections are documented in the section Product Description When connecting the cables to the CU8803 0000 proceed according to the following sequence Switch off all the devices that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables b...

Страница 14: ...and USB together via a Cat 6A cable The CU8803 transmitter box provides power to the Control Panel via the Cat 6A cable which also transfers DVI and USB The power supply socket of the panel is not used Don t connect power supply socket if using One Cable technology Attention If using the CP Link 4 One Cable Display Link technology do not connect anything to the power supply socket of the Panel The...

Страница 15: ...00 CP Link 4 transmitter box is maintenance free 4 3 Shutting down 4 3 1 Disposal Observe national electronics scrap regulations Note Observe the national electronics scrap regulations when disposing of the device In order to dispose of the device it must be removed and fully dismantled Housing components polycarbonate polyamide PA6 6 are suitable for plastic recycling Metal parts can be sent for ...

Страница 16: ...lled size With a height of 100 mm the module dimensions exactly match those of the Beckhoff Bus Terminals Together with the lowered connector surfaces this means that it can be used in a standard terminal box with a height of 120 mm front view left view top view 14 CU8803 0000 ...

Страница 17: ...es USB 100 Mbit s Power Supply 24 VDC 15 to 20 protected against polarity reversal To meet the UL requirements use 4 A fuse or class 2 power supply max current consumption with Control Panel app 4 7 A Dimensions W x H x D app 70 mm x 100 mm x 80 mm Weight app 745 g Permissible ambient temperature 0 C to 55 C operation 25 C to 70 C transport storage Permissible relative humidity 5 to 95 no condensa...

Страница 18: ...o KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services world wide support design programming and commissioning of complex automation s...

Страница 19: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical modifications Note Technical modifications t...