Beckhoff CPX37**-0010 Series Скачать руководство пользователя страница 38

Appendix

CPX37xx-0010

38

Version: 0.1

10.3

Connection Kits/ Connecting Cables/ Accessories

One 4-pole power supply connector is provided with the Panel PC. Optionally prefabricated connection
cables for the network connection are available.

Connecting ca-
bles

Network cable with IP65 connector

C9900-K281

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 3
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K282

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 5
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K283

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 10
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K284

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 15
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K285

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 20
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K286

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 30
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K287

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 40
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

C9900-K288

network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 50
m, assembled, Harting push-pull Ethernet connector IP 65, second
end RJ45, IP 20

Accessories

Mounting arm adapter

C9900-M763

Rotatable and tiltable mounting arm adapter for customised Multi-
touch Panel PC CPX37xx-0010, for Rittal and Rolec mounting arm
systems with 48 mm tube, wiring through the mounting arm. For
mounting four M6 tapped holes at a distance of 100 x 100 mm and 70
x 130 mm. Turnable by customer, not mounted at the factory.

Содержание CPX37**-0010 Series

Страница 1: ...Installation and operating instructions CPX37xx 0010 Multi touch Panel PC for use in hazardous locations zone 2 22 0 1 2018 05 09 Version Date...

Страница 2: ......

Страница 3: ...interfaces 18 4 3 1 Power supply X101 18 4 3 2 LAN1 LAN2 X104 X105 19 4 3 3 USB output X102 X103 19 4 3 4 Ground 19 4 3 5 Access to the battery and the CFast card slot 20 5 Mounting and wiring 22 5 1...

Страница 4: ...Table of Contents CPX37xx 0010 4 Version 0 1 10 2 Approvals for USA and Canada 37 10 3 Connection Kits Connecting Cables Accessories 38 10 4 Support and Service 39...

Страница 5: ...a diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH O...

Страница 6: ...serious injury WARNING Risk of injury Note this warning Hazard with medium risk of death or serious injury CAUTION Personal injuries Note this warning Hazard with a low degree of risk which could lea...

Страница 7: ...Notes on the documentation CPX37xx 0010 7 Version 0 1 1 2 Documentation issue status Version Comment 0 1 Preliminary Version...

Страница 8: ...mounting arm systems with 48mm tube C9900 M763 The Panel PC has no sparking components and is designed for a working environment that meets the requirements of protection class IP 65 The specified lim...

Страница 9: ...n explosive atmosphere is ensured Switch off the power supply and ensure that no explosive atmosphere occurs when the CFast card is replaced Switch off the power supply and ensure that no explosive at...

Страница 10: ...Switch off the power supply and ensure that no explosive atmosphere occurs when the CFast card is replaced Switch off the power supply and ensure that no explosive atmosphere occurs when changing the...

Страница 11: ...uous serial number markings and a production date on the name plate The Panel PC CPX37xx 0010 is certified for potentially explosive areas and bears the following ATEX DEKRA 18ATEX0053 X II 3G Ex nA I...

Страница 12: ...ic components which may be destroyed by electrostatic discharge when touched Observe the safety precautions against electrostatic discharge according to DIN EN 61340 5 1 3 Working with networks Limit...

Страница 13: ...nstructed regularly about relevant safety aspects and is familiar with the operating manual and in particular the safety instructions contained herein the operation manual is in good condition and com...

Страница 14: ...g should be used Table 1 Dimensions and weight of the individual Panels CPX3715 CPX3719 CPX3721 Dimensions W x H x D 375 x 290 9 x 70 mm 445 1 x 364 8 x 70 mm 549 8 x 330 3 x 70 mm Weight approx 6 9 k...

Страница 15: ...l PC series is characterised by a modern operating concept with multi touch display as well as an advanced elegant device design The mounting arm Panel PC is suitable for use in hazardous locations zo...

Страница 16: ...to the interfaces The interface of the Panel PC are located at the back side of the housing and at the side Fig 1 Connection block of the Panel PC CPX37xx 0010 with all interfaces Fig 2 CFast card slo...

Страница 17: ...nuous serial number markings and a production date on the name plate The Panel PC CPX37xx 0010 is certified for potentially explosive areas and bears the following ATEX DEKRA 18ATEX0053 X II 3G Ex nA...

Страница 18: ...ecified for 7 5 A and can lift conductive cross sections of 1 5 mm2 The power supply for the Panel PC is established via the socket X101 The power supply connector is included in delivery The power su...

Страница 19: ...ailable 4 3 3 USB output X102 X103 X102 X103 Socket USB A 2 port M23 The USB interface X102 X103 connector type A are connecting peripheral devices with USB connection USB 2 0 standard is supported Pi...

Страница 20: ...4 3 5 Access to the battery and the CFast card slot The battery and the CFast card slot are located behind a cover plate at the side of the Panel PC After removing the screws with a star screwdriver T...

Страница 21: ...ion 0 1 Removing the cover plate allows access to the CFast card slot and the battery WARNING Danger of Explosion Replace battery only with the identical type or an alternative type recommended by the...

Страница 22: ...e Panel PC Circulation of air In order to ensure adequate ventilation of the Panel PC 20 cm free space is required around the PC for air circulation Please note the following points during installatio...

Страница 23: ...to peripheral equipment Establish a low impedance connection from the earthing point on the Panel PC housing to the central earthing point on the control cabinet wall in which the Panel PC is being in...

Страница 24: ...is tightened carefully clockwise using a hook wrench SW 58 62 2 Also the mounting arm tube is locked by tightening the Allen screw 3 with the 3 mm Allen key with a torsion moment of 4 0 till 4 5 mm O...

Страница 25: ...Mounting and wiring CPX37xx 0010 25 Version 0 1 NOTE Tolerance of the mounting arm tube diameter The mounting arm tube must have a diameter of 48 mm with a maximum tolerance of 0 1 mm 0 8 mm...

Страница 26: ...rfaces When connecting cables to the Panel PC please adhere to the following order Disconnect the Panel PC from the power supply Connect all cables at the Panel PC and at the devices to be connected E...

Страница 27: ...ou take the voltage drop as a function of the cable cross section as well as voltage fluctuations of your distribution voltage into account so that is secured that the voltage doesn t fall under 22 V...

Страница 28: ...Mounting and wiring CPX37xx 0010 28 Version 0 1 5 2 3 Fitting the power supply...

Страница 29: ...off while the software is running is very high NOTE Switch off power supply When you have shut down the Industrial PC you have to switch off power supply for at least 10 seconds before rebooting the...

Страница 30: ...For hardware problems please contact the Beckhoff Service 6 4 Emergency procedures In case of fire the Panel PC should be extinguished with powder or nitrogen 6 5 Shutting down Disposal Observe nation...

Страница 31: ...ntrol does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the manufacturer of the machine or the software Malfunction of the...

Страница 32: ...Assembly dimensions CPX37xx 0010 32 Version 0 1 8 Assembly dimensions CPX3715 0010...

Страница 33: ...Assembly dimensions CPX37xx 0010 33 Version 0 1 CPX3719 0010...

Страница 34: ...Assembly dimensions CPX37xx 0010 34 Version 0 1 CPX3721 0010...

Страница 35: ...2 USB 2 0 interfaces Protection class IP65 Shock resistance Sinusoidal vibration EN 60068 2 6 10 bis 58 Hz 0 035 mm 58 bis 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration...

Страница 36: ...Explosive atmospheres Part 15 Equipment protection by type of protection n EN 60079 31 2014 Explosive atmospheres Part 31 Equipment dust ignition protection by enclosure t IECEx Standard Description I...

Страница 37: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eq...

Страница 38: ...Harting push pull Ethernet connector IP 65 second end RJ45 IP 20 C9900 K285 network cable for CP32xx CP37xx CPX37xx and CP72xx length 20 m assembled Harting push pull Ethernet connector IP 65 second...

Страница 39: ...mponents there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support of...

Отзывы: