1.1  Notes on the Documentation 

This description is only intended for the use of trained specialists in control and automation engineering 
who are familiar with the applicable national standards. It is essential that the following notes and 
explanations are followed when installing and commissioning these components. 

The responsible staff must ensure that the application or use of the products described satisfy all the 
requirements for safety, including all the relevant laws, regulations, guidelines and standards. 

1.1.1 Liability Conditions 

The documentation has been prepared with care. The products described are, however, constantly under 
development. For that reason the documentation is not in every case checked for consistency with 
performance data, standards or other characteristics. In the event that it contains technical or editorial 
errors, we retain the right to make alterations at any time and without warning. No claims for the 
modification of products that have already been supplied may be made on the basis of the data, diagrams 
and descriptions in this documentation. 

All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard. 

1.1.2 Trademarks 

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, Safety over EtherCAT

®

, TwinSAFE

®

 and XFC

®

 are registered 

trademarks of and licensed by Beckhoff Automation GmbH. 
Other designations used in this publication may be trademarks whose use by third parties for their own 
purposes could violate the rights of the owners. 

1.1.3 Patent Pending 

The EtherCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications 
or registrations in various other countries. 
The TwinCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP0851348, US6167425 with corresponding applications or registrations in various other 
countries. 

1.1.4 Copyright 

©

 Beckhoff Automation GmbH & Co. KG. 

The reproduction, distribution and utilization of this document as well as the communication of its contents 
to others without express authorization are prohibited. Offenders will be held liable for the payment of 
damages. All rights reserved in the event of the grant of a patent, utility model or design. 

1.1.5  State at Delivery 

All the components are supplied in particular hardware and software configurations appropriate for the 
application. Modifications to hardware or software configurations other than those described in the 
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. 

1.1.6 Delivery conditions 

In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply. 

CP6600-0001-0020/ CP6606-0001-0020 

Содержание CP6600-0001-0020

Страница 1: ...Installation and Operating instructions for CP6600 0001 0020 CP6606 0001 0020 Economy Built in Panel PC Version 1 3 Date 2017 12 05...

Страница 2: ......

Страница 3: ...2 Appropriate Use 8 2 3 Access to the connectors 8 2 4 Interfaces 9 2 4 1 Power Supply X101 9 2 4 2 Network connection LAN1 X 102 9 2 4 3 EtherCAT connection X 103 9 2 4 4 USB output X 104 X 105 9 2 4...

Страница 4: ...First switching on and driver installation 18 4 2 Operation 18 4 3 Servicing and maintenance 19 4 3 1 Cleaning 19 4 3 2 Maintenance 19 4 3 3 Replacing the battery on the motherboard 19 4 4 Emergency p...

Страница 5: ...red trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of t...

Страница 6: ...injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety advise adjoi...

Страница 7: ...the equipment must first be switched off after which the Panel PC is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of the Panel PC Items of...

Страница 8: ...the housing of the Panel PC Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Panel PC is used national regulation...

Страница 9: ...l PC offers the following benefits 10 1 inch TFT display 1024 x 600 WSVGA CP6600 0001 0020 or 7 inch TFT display 800 x 480 WVGA CP6606 0001 0020 touch screen aluminium front with sheet steel rear cove...

Страница 10: ...s accommodated in a steel housing with aluminium front The Panel PC is installed in the front of control cabinets for wall installation the wall mounting frame with order option C9900 M317 is necessar...

Страница 11: ...to a 10 100BASE T Local Area Network LAN 2 4 3 EtherCAT connection X 103 The RJ 45 connector X103 allows the PC to be connected to an EtherCAT Network 2 4 4 USB output X 104 X 105 The two USB interfa...

Страница 12: ...n WARNING Replace battery only with the identical type or an alternative type recommended by the manufacturer Notice correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not...

Страница 13: ...ion does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours must be allo...

Страница 14: ...ion the Panel PC in such a way that reflections on the screen are avoided as far as possible Use the position of the screen as a guide for the correct installation height it should be optimally visibl...

Страница 15: ...ers For the cutout dimension of the Panel PC see chapter Technical Data the wall thickness is between 1 mm and 5 mm 1 Insert the Panel PC into the cutout 2 Release the clamping levers with a 2 5 mm Al...

Страница 16: ...unting frame The wall mounting frame must be flush mounted in the wall and may not overlap the finished plaster A maximum of 5 mm behind the finished plaster can be adjusted with the ball catch Ensure...

Страница 17: ...ting of the Panel PC The ball catch counter parts are delivered with the wall mounting frame and have to be screwed onto the back side of the CP6606 0001 0020 The needed countersunk head screws M3x6 a...

Страница 18: ...e cable 1 Strip insulation from the cable ends Length of stripped conductor is 8 9 mm 2 Screw together the cable ends in the 5 pole plug connector in accordance with wiring diagram Applying the strain...

Страница 19: ...anel PC please adhere to the following order Disconnect the Panel PC from the power supply Connect all cables at the Panel PC and at the devices to be connected Ensure that all screw connections betwe...

Страница 20: ...hen you have shut down the Panel PC you have to switch off power supply for at least 10 seconds before rebooting the system After resetting power supply the Panel PC will start booting automatically 4...

Страница 21: ...ce correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be protected against sunlight and moisture The used battery m...

Страница 22: ...PC Cable not connected Check power supply cable 1 Correctly connect cable 2 Call Beckhoff Service Panel PC boots software starts but control does not operate correctly Cause of the fault is either in...

Страница 23: ...ns 6 Assembly dimensions CP6600 0010 0020 Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions are in mm CP6600 0001 0020 CP...

Страница 24: ...ly dimensions CP6606 0010 0020 Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions are in mm 22 CP6600 0001 0020 CP6606 000...

Страница 25: ...pter with RJ 45 connection 2 USB 2 0 interfaces 1 serial interface RS232 Protection class Front side IP54 rear side IP20 Shock resistance Sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 5...

Страница 26: ...rstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assistance helping...

Страница 27: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operati...

Отзывы: