Technical data 

Dimensions 

Dimensions (W x H x D):

   226 x 196 x 93 mm (without Control Panel) 

with CD-ROM (W x H x D): 

226 x 196 x 107 mm (without Control Panel) 

 
Weight:

 

9.5 kg (basic configuration) 

Do not use the PC in areas 
of explosive hazard 

The Industrial PC may not be used in areas of explosive hazard. 

 

 

The following conditions must be observed during operation: 

Environmental conditions 

Ambient temperature:

  

0 to 55°C 

Atmospheric humidity:

 

Maximum 95%, non-condensing 

Shock resistance 

Sinusoidal vibration:   
(EN 60068-2-6)

 

10 to 58 Hz:

 

0.035 mm 

 

58 to 500 Hz:  0.5 G (~ 5 m/ s

2

)  

During reading of CD-ROM:

 

10 to 58 Hz:

 

0.019 mm  

 

58 to 500 Hz:  0.25 G (~ 2.5 m/ s

2

Impact: 
(EN 60068-2-27/ -29)

 

5 G (~ 50 m/ s²), duration: 30 ms 

During reading of CD-ROM:

 

5 G (~ 50 m/ s²), duration: 11 ms 

Protection class 

Protection class:

 

IP20

 

Power supply 
24 V

DC

 power supply unit 

Supply voltage:

  

24 V

DC

 

Power consumption:

 

100 W for the basic version 

Electromagnetic 
Compatibility (EMC) 

Interference resistance:

 

according to EN 61000-6-2

  

Emitted resistance:

 

according to EN 61000-6-4 

Transport and storage 

The same values for atmospheric humidity and shock resistance are to be 
observed during transport and storage as in operation. The shock 
resistance during transport can be improved by means of suitably packing 
the Industrial PC. The ambient temperature during storage and transport 
must be between -20°C and +65°C. 

i

 

Note

 

Pixel errors in the TFT display are production-caused and represent 
no complaint-reason! 

 

 

Approvals 

 

FCC: Federal Communications Commission 
Radio Frequency Interference Statement 

FCC Approval for USA 

This equipment has been tested and found to comply with the limits for a 
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in 
which case the user will be required to correct the interference at his own 
expense. 

 

FCC: Canadian Notice 

FCC Approval for Canada 

This equipment does not exceed the Class A limits for radiated emissions 
as described in the Radio Interference Regulations of the Canadian 
Department of Communications. 

 

Содержание CP63 Series

Страница 1: ...Installation and Operating instructions for Built in Panel PC CP63xx Version 1 3 Date 2006 01 11...

Страница 2: ......

Страница 3: ...npacking 8 Installation of the PC in the control cabinet 9 Earthing measures 9 Power supply 10 Connecting devices 11 Connecting cables 11 Verifying the voltage and connecting 11 Operating Instructions...

Страница 4: ...he meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains...

Страница 5: ...equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been...

Страница 6: ...National regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machin...

Страница 7: ...plant engineering applications Structure Opening the housing To open the PC housing release the screw 1 by one turn using a screwdriver The plastic cap 2 can be then be pulled forward thereby releasi...

Страница 8: ...asic configuration The computer chassis can now be removed from the housing The power supply 1 and the hard disk 2 are located in the lower part of the chassis The slot motherboard 3 is located in the...

Страница 9: ...o be used while a PC keyboard can be connected to the lower PS 2 connector 7 VGA connection VGA A 15 pin SUB D socket connector 5 allows a VGA monitor to be connected free slot free slot A free slot 7...

Страница 10: ...ns in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur...

Страница 11: ...e unit is in its mounting position the ventilation openings must not be obstructed Warning Extreme environmental conditions should be avoided as far as possible Protect the rear of your PC from dust h...

Страница 12: ...ower supply unit Output voltages from the 24 V power supply unit Current loading maximum 5 V 8 A 5 V 0 5 A 12 V 4 A 12 V 0 5 A 3 3 V 4 A 5 V VSB 0 5 A Pin assignment and fuse protection Pin assignment...

Страница 13: ...ces that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Conn...

Страница 14: ...software is writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by swit...

Страница 15: ...as to be replaced according to the rules of the board manufactorer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufactur...

Страница 16: ...incorrect Other cause Remove floppy disk or CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault...

Страница 17: ...C Beckhoff Support Support offers you comprehensive technical assistance helping you no only with the application of individual Beckhoff products but also with other wide ranging services world wide s...

Страница 18: ...re to be observed during transport and storage as in operation The shock resistance during transport can be improved by means of suitably packing the Industrial PC The ambient temperature during stora...

Отзывы: