Foreword 

 

Foreword 

Notes on the Documentation 

This description is only intended for the use of trained specialists in control and automation engineering 
who are familiar with the applicable national standards. It is essential that the following notes and 
explanations are followed when installing and commissioning these components. 
The responsible staff must ensure that the application or use of the products described satisfy all the 
requirements for safety, including all the relevant laws, regulations, guidelines and standards. 

Liability Conditions 

The documentation has been prepared with care. The products described are, however, constantly under 
development. For that reason the documentation is not in every case checked for consistency with 
performance data, standards or other characteristics. In the event that it contains technical or editorial 
errors, we retain the right to make alterations at any time and without warning. No claims for the 
modification of products that have already been supplied may be made on the basis of the data, diagrams 
and descriptions in this documentation. 

All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard. 

Trademarks 

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 are registered 

trademarks of and licensed by Beckhoff Automation GmbH. 
Other designations used in this publication may be trademarks whose use by third parties for their own 
purposes could violate the rights of the owners. 

Patent Pending 

The EtherCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications 
or registrations in various other countries. 
The TwinCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP0851348, US6167425 with corresponding applications or registrations in various other 
countries. 

Copyright 

©

 Beckhoff Automation GmbH & Co.KG. 

The reproduction, distribution and utilization of this document as well as the communication of its contents 
to others without express authorization are prohibited. Offenders will be held liable for the payment of 
damages. All rights reserved in the event of the grant of a patent, utility model or design. 

State at Delivery 

All the components are supplied in particular hardware and software configurations appropriate for the 
application. Modifications to hardware or software configurations other than those described in the 
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG. 

Delivery conditions 

In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co.KG apply.

CP6207-xxxx-0020 

Содержание CP6207 0020 Series

Страница 1: ...Installation and Operating instructions for Economy built in Panel PC CP6207 xxxx 0020 Version 1 0 Date 2019 09 09...

Страница 2: ...0 Installation in a control cabinet wall 10 Earthing measures 10 Mounting of the Panel PC 11 Power Supply Connection 12 Beckhoff power supply technology 12 Pin assignment of the connector 13 Fitting t...

Страница 3: ...tion 21 Beckhoff Support Service 22 Beckhoff branches and partner companies 22 Beckhoff Headquarters 22 Beckhoff Support 22 Beckhoff Service 22 Appendix 23 Assembly dimensions 23 Technical data 24 App...

Страница 4: ...S are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate th...

Страница 5: ...isk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety advis...

Страница 6: ...itched off must be secured against being switched on again The Industrial PC s power supply unit must be supplied with 24VDC Do not open the power supply unit while voltage is applied CAUTION The supp...

Страница 7: ...s familiar with all the functions of the software installed on the Industrial PC to which he has access National regulations depending on the machine type Depending on the type of machine and plant in...

Страница 8: ...with an optional interface according to the order option DVI Digital Visual Interface X103 DVI out The DVI connection is used for transferring the video signal DVI D standard is supported USB Interfac...

Страница 9: ...F Card and the Battery Access to the CF Card and the battery After solving the two crosshead screws 1 und 2 the cover cap can be removed and allows access to the CF Card and the battery cover cap 2 1...

Страница 10: ...hat moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately...

Страница 11: ...allation height it should be optimally visible for the user at all times The PC should not be exposed to direct sunlight When the unit is in its mounting position the ventilation openings must not be...

Страница 12: ...cutout dimensions Similar pictures Mounting of the Panel PC Clamping levers Release clamping levers Insert the PC into the cutout Release the clamping levers with a No 2 5 Allen key Folding them out...

Страница 13: ...In this case the PC shuts down via the battery However over time this reduces the service life of the battery The new Beckhoff power supply technology approach addresses this problem and now offers t...

Страница 14: ...off in order to avoid total discharge of the battery For a detailed functional description please refer to section Connecting Power Supply Pin assignment of the connector The power supply and the exte...

Страница 15: ...cified for 16 A and can lift conductive cross sections until 1 5 mm2 Fitting the connector to the cable So the connector is fitted to the cable 1 Strip insulation from the cable ends Length of strippe...

Страница 16: ...rted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting the supply voltage and shut down via th...

Страница 17: ...gram the circuit of PC_ON and Power Status is symbolical Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output Note Connection of the Battery Pack and UPS Outpu...

Страница 18: ...isconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Connect all data transfer cables i...

Страница 19: ...amage by switching off while the software is running is very high Switch off power supply Attention When you have shut down the Industrial PC you have to switch off power supply for at least 10 second...

Страница 20: ...d manufacturer See also chapter Access to the CF Card and the Battery Danger of Explosion WARNING Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recom...

Страница 21: ...river CD provided Installation on the PC Installation To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial PC D...

Страница 22: ...Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the manufacturer of the machi...

Страница 23: ...rstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only with the...

Страница 24: ...e mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimensions are in mm front view rear view with install measure bottom view M4 groundi...

Страница 25: ...kaging of the Industrial PC can improve the resistance to impact during transport The ambient temperature during storage and transport must be between 20 C and 65 C Pixel errors Note Pixel errors in t...

Отзывы: