Fault correction
Fault Cause Measures
The Control Panel shows no
function when the Industrial PC has
been started
No power supply to Industrial PC
CP-Link-cable connected not or
exchanged
Check power supply cable
1. Correctly connect CP-
Link-cable: Put the plug
with the red marking into
the socket with the red
point.
2. Call Beckhoff Service
The Industrial PC does not boot
fully
Floppy disk in the drive
Hard disk damaged (e.g. by
switching off while software running)
Setup settings are incorrect
Other cause
Remove floppy disk and
press any key
1. Boot with boot diskette
2. Start SCANDISK
Check the setup settings
Call Beckhoff Service
Computer boots, software starts,
but control does not operate
correctly
The cause of the error is in the
software or in parts of the
equipment outside the control panel
Call the manufacturer of the
machine or the software
Floppy disk access error
Faulty disk
Faulty disk drive
Check disk in another drive
Call Beckhoff Service
The control panel only exhibits
partial function, or only some of the
time - e.g., no or dark picture,
although disk drive operates when
switched on
Faulty fluorescent bulb in the
display
Defective components in control
panel
Replace fluorescent tube in
the display in accordance
with description
Call Beckhoff Service
CP60xx