Beckhoff C9900-M Series Скачать руководство пользователя страница 6

Foreword

C9900-Mxxx

6

Version: 1.0

1.2

Safety instructions

Safety regulations

Please note the following safety instructions and explanations!
Product-specific safety instructions can be found on following pages or in the areas mounting, wiring,
commissioning etc.

Exclusion of liability

All the components are supplied in particular hardware and software configurations appropriate for the
application. Modifications to hardware or software configurations other than those described in the
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG.

Personnel qualification

This description is only intended for trained specialists in control, automation and drive engineering who are
familiar with the applicable national standards.

Description of symbols

In this documentation the following symbols are used with an accompanying safety instruction or note. The
safety instructions must be read carefully and followed without fail!

 DANGER

Serious risk of injury!

Failure to follow the safety instructions associated with this symbol directly endangers the life and health of
persons.

 WARNING

Risk of injury!

Failure to follow the safety instructions associated with this symbol endangers the life and health of per-
sons.

 CAUTION

Personal injuries!

Failure to follow the safety instructions associated with this symbol can lead to injuries to persons.

NOTE

Damage to the environment or devices

Failure to follow the instructions associated with this symbol can lead to damage to the environment or
equipment.

Tip or pointer

This symbol indicates information that contributes to better understanding.

Содержание C9900-M Series

Страница 1: ...Installtation and Operating instruction C9900 Mxxx Built in EtherCAT button module 1 0 2018 09 19 Version Date...

Страница 2: ......

Страница 3: ...with 4 pin round connector 11 3 3 3 Power supply plug 11 3 3 4 Sensor cable for emergency stop 11 3 3 5 Sensor cable 90 for emergency stop 12 3 3 6 M12 EtherCAT cable for highly flexible applications...

Страница 4: ...Table of contents C9900 Mxxx 4 Version 1 0...

Страница 5: ...s and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH...

Страница 6: ...re familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions m...

Страница 7: ...xposed to extreme variations in tempera ture make sure that moisture condensation does not form on or inside the device 2 2 Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not...

Страница 8: ...e activated in the colors red green blue and white as a result of which the operator can immediately read off feedback messages that are indicated for example by a change of color or by flashing The s...

Страница 9: ...ia the 4 pin M12 socket The protection class of the round connector is equivalent to the IP67 standard Pin Signal Pin Signal 1 24 V DC 3 GND 2 GND 4 24V DC 3 2 2 EtherCAT IN OUT The EtherCAT connectio...

Страница 10: ...nnector Accessories Description C9900 K741 Power cable for Control Panel drag chain suitable with 90 4 pin round connector 10 m consisting of Power cable 2 x 0 75 mm conforming to UL cores color coded...

Страница 11: ...Power cable for Control Panel drag chain suitable with 4 pin round connector 20 m consisting of Power cable 2 x 0 75 mm conforming to UL cores color coded Side A Round 4 pin socket Side B not used 3 3...

Страница 12: ...e M12 angled 90 pin 4 pin A coded open end 5 m ZK2000 6300 0100 Sensor cable M12 angled 90 pin 4 pin A coded open end 10 m 3 3 6 M12 EtherCAT cable for highly flexible applications Accessories Descrip...

Страница 13: ...Before you can use the device it must first be created in the TwinCAT System Manager Proceed as follows 1 Click at the top in the menu on File New Project and create a new TwinCAT XAE Project 2 In th...

Страница 14: ...quest with Yes in order to look for boxes 6 Confirm the request whether to enable FreeRun with Yes The device is inserted as a box in the tree view and displayed with the respective inputs and outputs...

Страница 15: ...Product description C9900 Mxxx 15 Version 1 0 3 5 1 C9900 M993...

Страница 16: ...Product description C9900 Mxxx 16 Version 1 0 3 5 2 C9900 M994...

Страница 17: ...Product description C9900 Mxxx 17 Version 1 0 3 5 3 C9900 M995...

Страница 18: ...Product description C9900 Mxxx 18 Version 1 0 3 5 4 C9900 M997...

Страница 19: ...Product description C9900 Mxxx 19 Version 1 0 3 5 5 C9900 M899...

Страница 20: ...Mounting C9900 Mxxx 20 Version 1 0 4 Mounting 4 1 Mounting the clamp straps max 1 2 Nm max 1 2 Nm max 1 2 Nm max 1 2 Nm Max wall thickness 4 mm...

Страница 21: ...Mounting C9900 Mxxx 21 Version 1 0 4 2 Mounting the push in strips Push in strips Clamping plate for push in strips The ordered push in strips are fixed behind the clamping plate...

Страница 22: ...Mounting C9900 Mxxx 22 Version 1 0 4 3 Push in strips...

Страница 23: ...Dimensions C9900 Mxxx 23 Version 1 0 5 Dimensions 5 1 C9900 M899...

Страница 24: ...Dimensions C9900 Mxxx 24 Version 1 0 5 2 C9900 M993...

Страница 25: ...Dimensions C9900 Mxxx 25 Version 1 0 5 3 C9900 M994...

Страница 26: ...Dimensions C9900 Mxxx 26 Version 1 0 5 4 C9900 M995...

Страница 27: ...Dimensions C9900 Mxxx 27 Version 1 0 5 5 C9900 M997...

Страница 28: ...th 100 m 100BASE Tx for EtherCAT In Out Data transfer rate 100MBit Data transfer medium Industrial Ethernet cable shielded at least CAT 5 LED ring lighting of the keys Red green blue white Emergency s...

Страница 29: ...9900 M993 Approx 980 g C9900 M994 Approx 980 g C9900 M995 Approx 790 g C9900 M997 Approx 710 g C9900 M899 Approx 670 g Operating temperature Operation 0 50 C Storage 20 C to 60 C Transport 20 C to 60...

Страница 30: ...components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support...

Отзывы: