The C6905 Industrial PC belongs to the series of compact Industrial PCs for space-saving control cabinet
installation. The device is suitable for various applications and requirements.

Thanks to the available processors, the Industrial PC can be used for the following applications, among
others:

• diverse automation and visualization tasks

• wide range of IoT tasks, for example when used as an IoT gateway

• simple HMI applications

• axis control

• short cycle times

• high-volume data handling

The basic configuration of the C6905 includes the following aspects:

• Intel

®

 processor

• 1 DVI connection, graphic adapter integrated in the Intel

®

 processor

• 2 x 100/1000BASE-T connections, on-board dual Ethernet adapter

• CFast

• 4 x USB

Содержание C6905

Страница 1: ...Manual EN C6905 Industrial PC 7 14 2021 Version 2 1...

Страница 2: ......

Страница 3: ...d unpacking 17 4 2 Installation in the control cabinet 18 4 2 1 Dimensions 19 4 2 2 Installation in the control cabinet 20 4 3 Connecting the Industrial PC 21 4 3 1 Grounding of the Industrial PC 22 4...

Страница 4: ...Table of contents C6905 4 Version 2 1...

Страница 5: ...CAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication...

Страница 6: ...th or serious injuries WARNING Disregarding the safety notice may lead to death or serious injuries CAUTION Disregarding the safety notice may lead to minor injuries Warning of damage to property NOTE...

Страница 7: ...ssipation please refer to the respective data sheet Ensure that only trained specialists with a control and automation technology background operate the Industrial PC Use by unauthorized persons can l...

Страница 8: ...ustrial PC can be used for the following applications among others diverse automation and visualization tasks wide range of IoT tasks for example when used as an IoT gateway simple HMI applications ax...

Страница 9: ...Access to battery and storage media 4 Protective conductor connection PE Low resistance protective earthing and functional earthing of the Industrial PC 5 DVI interface X109 Connection of a DVI capab...

Страница 10: ...C is equipped with an internal capacitive 1 second UPS uninterruptible power supply this is also supplied by the voltage The 1 second UPS does not serve to back up the operating system For further inf...

Страница 11: ...ort i210 connected via PCIe is usually suitable for cycle times 1 ms and for distributed clock applications with EtherCAT X103 X104 LAN2 LAN1 8 1 8 1 Fig 3 C6905_Ethernet interface pin numbering Table...

Страница 12: ...B interfaces based on device generation Generation USB interfaces C6905 0010 4x USB 2 0 C6905 0020 2x USB 3 0 2x USB 2 0 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7 8 9 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7 8 9 4 3 2 1...

Страница 13: ...Connection Pin Connection Pin Connection 1 TDMS Data 2 9 TDMS Data 1 17 TDMS Data 0 2 TDMS Data 2 10 TDMS Data 1 18 TDMS Data 0 3 TDMS Data 2 4 Shield 11 TDMS Data 1 3 Shield 19 TDMS Data 0 5 Shield...

Страница 14: ...isk activity The figure shows where the LEDs are located on the Industrial PC Fig 6 C6905 Status LEDs Table 8 Meaning of the Status LEDs LED Color flashing interval Meaning PWR Power green off Compute...

Страница 15: ...ple Table 9 Key name plate C6905 No Description 1 Model The last four digits indicate the device generation 2 Serial number BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Main memory 7 Storage media 8...

Страница 16: ...ex factory with an internal UPS under the order designation C9900 U214 The capacitive 1 second UPS continues to supply the processor with power if the power supply fails During this period persistent...

Страница 17: ...iate packaging of the Industrial PC in particular the original packaging can improve the vibration resistance during transport NOTE Hardware damage due to condensation Unfavorable weather conditions d...

Страница 18: ...C is designed for installation in control cabinets in machine and plant technology Please observe the environmental conditions prescribed for the operation see Chapter 9 Technical data 36 With the hel...

Страница 19: ...ng plate are used to prepare the control cabinet and to mount the device correctly in the control cabinet All dimensions are in mm Figure 10 illustrates the dimensions of the Industrial PC with the st...

Страница 20: ...in the control cabinet it must be furnished with the holes for the fastening screws according to the dimensions of the PC see Chapter 4 2 1 Dimensions 19 You need M4 screws for mounting After you hav...

Страница 21: ...evice To prepare the Industrial PC for operation it must be connected The first step is to ground the device Then you can connect the cables and the power supply An external power supply unit is requi...

Страница 22: ...arthing of the Industrial PC and thus avoid dangerous touch voltages EMC NOTE Hardware damage due to electromagnetic interference Using the Industrial PC without functional earthing can lead to hardwa...

Страница 23: ...ply Cables with a maximum cable cross section of 1 5 mm2 must be used for connecting the power supply To achieve the lowest possible voltage drop on the supply line we recommend connecting the maximum...

Страница 24: ...is shut down can lead to data loss Quit the running software and shut down the operating system before switching off the PC When the system is switched off or disconnected from its own power supply t...

Страница 25: ...Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual Starting the Beckhoff Device Manager for...

Страница 26: ...passwords are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you chang...

Страница 27: ...lectric shock Never disconnect the cables from the device during thunderstorms Before you remove the Industrial PC from the control cabinet you must follow the following steps 1 Shut down the operatin...

Страница 28: ...14 3 Remove the PC from the control cabinet You have successfully disassembled the PC Fig 14 C6905_Dismantling the control cabinet Disposal of the Industrial PC Be sure to observe the national electro...

Страница 29: ...onents and the replacement of other device components contribute to this Repair Only the manufacturer may repair the device If a repair should be necessary contact Beckhoff Service see Chapter 10 1 Se...

Страница 30: ...rs UPS battery pack 5 years 2 5 inch hard disk 5 years or after 20 000 operating hours at more than 40 C or after 30 000 operating hours at less than 40 C 3 5 inch hard disk 5 years irrespective of th...

Страница 31: ...e For example the following measures can be used Use conductive mats connected to the ground potential as underlays Dissipate possible charges from your own body by touching earthed metal e g control...

Страница 32: ...to these components Accessing the battery and CFast You can access the battery and the CFast via the cover on the left hand side To do this remove the four Torx TX10 screws and remove the cover see f...

Страница 33: ...ons Nominal voltage Nominal capac ity Diameter Height Weight CR2032 3 0 V 225 mAh 20 0 mm 3 20 mm 3 1 g Chapter 7 2 1 Access to device components 32 shows how to access the battery To change the batte...

Страница 34: ...f the BST USB flash drive according to the size of the backup copy of your operating system You can then keep the flash drive as a backup copy For this purpose the BST USB flash drives with SLC flash...

Страница 35: ...PC Other cause Check the power supply cable Call Beckhoff Service The Industrial PC does not boot fully Setup settings are incorrect Other cause Check the setup settings Call Beckhoff Service Computer...

Страница 36: ...58 Hz 0 035 mm 58 to 500 Hz 0 5 G approx 5 m s2 Shock resistance shock EN 60068 2 27 5 G approx 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference emission con...

Страница 37: ...PC which can be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with...

Страница 38: ...to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse inter...

Страница 39: ...6905_Name plate example 15 Fig 8 UPS function 16 Fig 9 C6905_Mounting plate 18 Fig 10 C6905_Dimensions with standard mounting plate 19 Fig 11 C6905_Control cabinet installation 20 Fig 12 Beckhoff Devi...

Страница 40: ...ce pin assignment 11 Table 5 USB interfaces based on device generation 12 Table 6 USB interface pin assignment 12 Table 7 DVI interface pin assignment 13 Table 8 Meaning of the Status LEDs 14 Table 9...

Страница 41: ......

Страница 42: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com C6905...

Отзывы: