background image

Installation Instructions 

 

 

14

 

6525 

 

 

Connecting Power Supply 

 

The external wiring consists of the connection of the power supply, the 
battery pack (optional) and the connection of customised components for 
shutting down the PC. 

 

Cable Cross Sections 

Note cable cross sections, 
avoid voltage drop!  

For the connection of the power supply, wiring  with a cable-cross-section 
of 1.5 mm

 must be used.  

With bigger distances between voltage source and PC, you take the 
voltage drop as a function of the cable-cross-section as well as voltage 
fluctuations of your distribution voltage into account, so that is secured that 
the voltage doesn't fall under 22 V at the power supply.  

Insert Fuse 

The power supply must be protected with maximum 16 A.

 

 
 

Configuration for shutting down the PC 

 

The connections for shutting down the Industrial PCs are established via 
the 

PC_ON

 input and the 

Power Status

 output.  

 

PC_ON and Power Status functions 

 

 

If the 

PC_ON

 input is connected to 24 V via a switch, the PC shuts 

down according to the rules. The PC_ON signal is inverted, i.e. the 
PC shuts down if the 24 V connection is live. 

 

If the 

PC_ON

 input is 

NOT

 connected by the user, the PC can be 

booted in the familiar way by connecting the supply voltage and shut 
down via the battery by switching off the supply voltage. 

 

Warning 

 

This procedure significantly reduces the service life of the rechargeable 
battery and should therefore not be used. 

 

 

 

Once the PC has shut down, the 

Power Status

 output is switched 

from 24 V to 0 V. Via this output a signal lamp can be connected or a 
contactor for de-energising the whole system. The maximum load for 
the Power Status output is 0.5 A and a suitable fuse should be 
provided. 

 

UPS output 

 

In order to maintain a screen display for the PC in the event of a power 
failure, the power supply unit is equipped with a 

UPS output

 for connecting 

a Control Panel. The maximum load for the output is 2.0 A. 

 

UPS output function 

 

 

The 24 V DC connection at the UPS output is live even after a power 
failure. The maximum load is 2.0 A. 

 

Once the PC has been de-energised via the UPS software, the 

UPS 

output

 is switched to 0 V. Any connected panel is thus switched off, 

and total discharge of the rechargeable battery is prevented. 

 
 

Содержание C6525

Страница 1: ...Installation and Operating instructions for Built in Industrial PC C6525 Version 1 1 Date 2021 11 15...

Страница 2: ......

Страница 3: ...easures 9 Mounting of the Industrial PC 10 Power Supply Connection 11 Beckhoff power supply technology 11 Pin assignment of the connector 12 Fitting the cable 13 Material for assembling the connectors...

Страница 4: ...ice 21 Beckhoff branches and partner companies 21 Beckhoff Headquarters 21 Beckhoff Support 21 Beckhoff Service 21 7 Assembly dimensions 22 8 Appendix 23 Technical data 23 Approvals 23 FCC Federal Com...

Страница 5: ...the meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contain...

Страница 6: ...of the equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that hav...

Страница 7: ...ible National regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such m...

Страница 8: ...hipset is given off directly to the surroundings View form the top Configuration The 6525 is a fanless Industrial PC with passive cooling and can hence be constructed completely without rotating parts...

Страница 9: ...Network 10 100BASE T The RJ 45 connector X109 allows the PC to be connected to a 10 100BASE T Local Area Network LAN Network 10 100 1000BASE T The RJ 45 connector X110 allows the PC to be connected t...

Страница 10: ...ations in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation oc...

Страница 11: ...m in order to ensure adequate ventilation of the PC Warning Extreme environmental conditions should be avoided as far as possible Protect the PC from dust moisture and heat The ventilation slots of th...

Страница 12: ...Industrial PC with clamping levers For installation the Industrial PC proceed as follows Release clamping levers Insert the Industrial PC into the cutout Release the clamping levers with a No 2 5 Alle...

Страница 13: ...e the PC shuts down via the battery However over time this reduces the service life of the battery The new Beckhoff power supply technology approach addresses this problem and now offers the user the...

Страница 14: ...is switched off in order to avoid total discharge of the battery For a detailed functional description please refer to section Connecting Power Supply Pin assignment of the connector The power supply...

Страница 15: ...nnector is specified for 16 A and can lift conductive cross sections until 1 5 mm2 Fitting the connector to the cable So the connector is fitted to the cable 1 Strip insulation from the cable ends Len...

Страница 16: ...rules The PC_ON signal is inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting the supp...

Страница 17: ...ing according to the wiring diagram the circuit of PC_ON and Power Status is symbolical Wiring diagram external switch and power supply i Note The battery pack can only be connected when the Industria...

Страница 18: ...connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in rec...

Страница 19: ...s the software is writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by...

Страница 20: ...aced according to the rules of the board manufacturer See also chapter Product Description Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recom...

Страница 21: ...led from the driver CD provided Installation on the PC Installation To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the I...

Страница 22: ...fully Setup settings are incorrect Other cause Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the...

Страница 23: ...GmbH Eiserstra e 5 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only...

Страница 24: ...mbly dimensions 22 6525 Assembly dimensions Warning The assembly of the unit must take place with the orientation diagrammed here Industrial PC C6525 All dimensions are in mm rear view side view top v...

Страница 25: ...are to be observed during transport and storage as in operation The shock resistance during transport can be improved by means of suitably packing the Industrial PC The ambient temperature during sto...

Отзывы: