background image

 

General instructions 

 

 
 

Operator's obligation to exercise diligence 

 

The operator must ensure that 

• 

the Industrial PC is only used for its intended use (see also 

Product Description

). 

• 

the Industrial PC is in a sound condition and in working order 
during operation. 

• 

the operation manual is in good condition and complete, and 
always available for reference at the location of the Industrial PC. 

• 

the Industrial PC is operated, maintained and repaired only by 
sufficiently qualified and authorised personnel. 

• 

the personnel is instructed regularly about relevant occupational 
safety and environmental protection aspects, and is familiar with 
the operating manual and in particular the safety notes contained 
herein. 

• 

none of the safety and warning notes attached to the Industrial PC 
are removed, and that all notes remain legible. 

 

National regulations  
depending on the machine 
type 

Depending on the type of machine and plant in which the Industrial PC is 
being used, there will be national regulations for the control of such 
machines and plant that the operator must observe. These regulations 
cover, amongst other things, the intervals between inspections of the 
controller. 
 
The operator must initiate such inspections in good time. 
 

 

Warning

 

 

Only trained persons may open the Industrial PC housing! 

The operator is responsible for ensuring that only trained electrical staff 
opens the housing of the Industrial PC. 
 

 

 

Procedure in the event of a 
fault 

In the event of a fault in the Industrial PC, appropriate measures can be 
determined with the aid of the list in the 

Fault correction

 section. 

 

 

Operator requirements 

Read the operating 
instructions 

Every user of the Industrial PC must have read these operating 
instructions. 
 

Software knowledge 

Every user must be familiar with any of the functions of the software 
installed on the PC that he can reach. 
 

 

C6240-1007 

Содержание C6240-1007

Страница 1: ...Installation and Operating instructions for Control Cabinet Industrial PC C6240 1007 Version 1 0 Date 2007 12 20...

Страница 2: ......

Страница 3: ...allation of the PC in the control cabinet 11 Earthing measures 11 Power Supply Connection with 100 240 VAC power supply unit 12 Mains Socket 12 Power supply cords 12 Power Supply Connection with 24 VD...

Страница 4: ...ff headquarters 21 Beckhoff Support 21 Beckhoff Service 21 Assembly dimensions 22 Configuration with 100 240 VAC Power Supply 22 Configuration with 24 VDC Power Supply optional 23 Appendix 24 Technica...

Страница 5: ...meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains t...

Страница 6: ...he plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial PC s power sup...

Страница 7: ...al regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines and...

Страница 8: ...Opening the Housing Front view of C6240 1007 configuration with 100 240 VAC power supply 2 1 1 Front view of C6240 1007 configuration with 24 VDC power supply optional Opening the housing After solvin...

Страница 9: ...shows the optional configuration of the PC with a removable hard disk drawer 1 for one Serial ATA hard disk drive and a slimline CD DVD ROM drive 2 instead of the standard CD DVD ROM drive The connec...

Страница 10: ...r supply unit optional with UPS Front view of the PC The picture shows the optional configuration of the PC with a multi DVD drive 1 instead of the standard CD DVD ROM drive The connections of the Ind...

Страница 11: ...he power supply unit When fitted without UPS the interface COM4 is located in one of the slots right beside the ATX slot COM2 and COM3 are located in a slot right beside the ATX slot VGA connection VG...

Страница 12: ...in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a d...

Страница 13: ...e and below the housing must be at least 50 mm in order to ensure adequate ventilation of the PC Warning Extreme environmental conditions should be avoided as far as possible Protect the PC from dust...

Страница 14: ...h at the PC housing main switch mains socket Power supply cords Power cords Europe In the area Europe you use the provided cable with inlet connector for non heating apparatus to connect the Industria...

Страница 15: ...t Current loading maximum 5 V 14 A 5 V 0 3 A 12 V 12 A 12 V 0 5 A 3 3 V 12 A 5 V VSB 1 5 A Connecting the power supply A 5 pin male plug connector with CAGE CLAMP connection see photo is installed at...

Страница 16: ...ief housing A B C D Fitting the connector Fitting the connector to the cable The plug is fitted to the cable as follows 1 Strip insulation from the cable ends insulation length 8 9 mm 2 Push the condu...

Страница 17: ...ribution voltage into account so that is secured that the voltage doesn t fall under 22 V at the power supply Insert Fuse The power supply must be protected with maximum 16 A PC_ON Power Status UPS ou...

Страница 18: ...ial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in receptacles of the data telecommunication networks Reconnect all devices to th...

Страница 19: ...Warning First shut down then switch off the PC If the Industrial PC is switched off as the software is writing a file to the hard disk the file will be destroyed Control software typically writes som...

Страница 20: ...ard has to be replaced according to the rules of the board manufacturer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manuf...

Страница 21: ...e driver CD provided Installation on the PC Installation To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial P...

Страница 22: ...d press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the pla...

Страница 23: ...5 D 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support offers you comprehensive technical assistance helping you no only with the applica...

Страница 24: ...imensions The following pages show diagrams of the Industrial PC with dimensions in mm Configuration with 100 240 VAC Power Supply Warning The assembly of the unit must take place with the orientation...

Страница 25: ...Assembly dimensions Configuration with 24 VDC Power Supply optional Warning The assembly of the unit must take place with the orientation diagrammed here C6240 1007 23...

Страница 26: ...nsport and storage The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation The shock resistance during transport can be improved b...

Отзывы: