Beckhoff AX5721 Скачать руководство пользователя страница 2

Seite 2/2

 

 

 

Technical data 

Max. single turn resolution: 32 bit 

Overview of sockets X41 (channel A) und X42 (channel B) 

 

Pin 

Endat 2.2 

BiSS C 

Output current 

1 n.c 

n.c 

0,25 A / channel

2 GND 

GND 

3 n.c 

n.c 

5V+  ±10% 

5V+  ±10% 

5 Data+ 

Data+ 

12 V 

12 V 

7 n.c 

n.c 

8 CLK+ 

CLK+ 

9 n.c. 

n.c. 

10 

GND sense 

GND sense 

11 n.c. 

n.c. 

12 

5V sense  ±10%  5V sense  ±10%

13 Data- 

Data- 

14 n.c. 

n.c. 

15 CLK- 

CLK- 

 

Installation of the digital encoder card 

CAUTION 

Caution – Do not work on live equipment! 

Disconnect the equipment at all poles from live parts and secure it against being switched on again, so that there is no possibility of 
uncontrolled movements of the equipment occurring. 

DANGER 

Caution – Danger of death! 

Due to the DC link capacitors dangerous voltage (875VDC) may persist at the DC link contacts “ZK+ and ZK- (DC+ and DC-)“ and 
“RB+ and RB-“ after the servo drive has been disconnected from the mains supply. After disconnecting the servo drive wait at 
AX5101 - AX5125 and AX520x; 

5 minutes

, at AX5140/AX5160/AX5172; 

15 minutes

, at AX5190/AX5191; 

30 minutes

 and at 

AX5192/AX5193; 

45 minutes

 and measure the voltage at the DC link contacts ZK+ and ZK- (DC+ and DC-). The device is safe 

once the voltage has fallen below 50 V. 

Attention 

Destruction of the digital encoder card through electrostatic charging! 

The digital encoder card is an ESD-sensitive component. Follow the usual ESD safety procedures when handling the card (anti-
static wrist straps, earthing of the relevant components, etc.). 

 

  Fully release the bolt (1). 

  Remove the panel (2). 

  Carefully insert the digital card (3) into the opening in the direction of 

the arrow. The slot has guides for the card on the short sides. Ensure 
that the card is inserted into these guides. 

  Tighten the bolt (4). 

 
 
 

Error messages related to the Encoder Option Card 

F870 “Encoder not ready” – execute the RESET command (S-0-0099) 
F872 “Error flag active” – status changes to “Safe op”. Restart required 
F873 „Get position timeout“ – status changes to “Safe op”. Restart required 
F874 „ Crc memory error – execute the RESET command (S-0-0099) 
F875 „No EnDat 2.2 encoder connected“ – execute the RESET command (S-0-0099) 
F876 „UART Error“ – execute the RESET command (S-0-0099) 
F877 „Out of memory“ – execute the RESET command (S-0-0099) 
F879 „Calibration error“ – execute the RESET command (S-0-0099)  
F87A „AX572x power supply error“ – execute the RESET command (S-0-0099)  
F87C „AX572x protocol not supported“ – execute the RESET command (S-0-0099)  
F87D „AX572x wrong parameter“ – execute the RESET command (S-0-0099) 
Copyright 
© Beckhoff Automation GmbH & Co. KG 
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization 
are prohibited. 
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. 

Scope of supply 

The scope of supply includes the following components: 
High Resolution Digital encoder card AX572x, technical documentation and packaging 
If one of the components is damaged please notify the logistics company and Beckhoff Automation GmbH & Co. KG immediately. 

 

Отзывы: