Electrical installation
102
───
Version: 4.3
AM8000 and AM8500
9.2
Connector assignment
Beckhoff offers various power connectors and feedback connectors.
All connectors are IP65 rated. A protective conductor connection ac-
cording to VDE 0627 is provided on the housing.
9.2.1
OneCableTechnology
The following tables show the connector assignment on the motor
side:
iTec connector
Pin assignment iTec connector
iTec connector
Contact
Function
Core identifica-
tion
A
U
Black/1
B
W
Black/3
C
V
Black/2
1
Brake+
5
2
Brake-
6
3
Temp/
OCT+
White
4
Temperature-/
OCT-
Blue
5
---
---
PE
PE
Green/yellow
M23 connector
Pin assignment M23 connector
M23 connector
Contact
Function
Core identifica-
tion
A
U
Black/1
B
V
Black/2
C
W
Black/3
D
PE
Green/yellow
E
Temperature-/
OCT-
Blue
F
Shield
Shield
G
Brake+
Black/5
H
Temp/
OCT+
White
L
Brake-
Black/6