Run a drain line from the evaporator 

coil drain to the pump. Use the flexible 

plastic pipe where the code permits. 
Insert the pipe 1” below the pump 

cover. Do not install inlet drain line that 

would interfere with operation of floats. 

Connect outlet tubing (copper or vinyl) 
to discharge on pump. Do not run 

tubing vertical more than is 

recommended by the lift on each unit. 

For good flow, slant the horizontal run 
downward toward the drain. Each unit 

comes standard with a check valve for 

connecting to ½” O.D. copper tubing. A 

copper tube adapter is included for vinyl 

hose hook-up. 

RULES FOR SAFE OPERATION 

1.  Carefully read the Owners Manual and rules for safe operation. 

2.  All wiring must conform to local codes. Use the National Electric Code if 

local code is nonexistent. 

3. 

CAUTION!

 To reduce risk of electric shock disconnect from power supply 

before servicing, pull the plug on models which have plug-in connections. 

4.  Do not handle the pump with wet hands or when standing in water as fatal 

shock could occur. Disconnect main power before handling unit for ANY 
REASON! 

5.  Protect the power cable from coming in contact with sharp objects. 

6.  Do not kink power cable and never allow the cable to come in contact with 

oil, grease, hot surfaces or chemicals. 

7.  Make certain that line voltage conforms to the voltage specified on motor 

and nameplate. 

8. 

WARNING!

 To reduce risk of electrical shock, connect only to a properly 

grounded grounding type receptacle.  

INSTALLATION 

Select a location for the pump. It should be 

as near as possible to the air conditioning 

coil but avoid any water spray or drops on or 

near the motor and switch cover

. The pump 

must be

 

level.

 The inlet hole must be below 

the coil drain. 

Carefully unpack the pump. Remove the 
switch cover. Check each float rod for “free” 

action. 

PIPING 

 

 

COVER 

PRIMARY SWITCH 

TERMINAL BLOCK 

 

FLOAT 

TANK 

STAND 

OUTLET 

INLET 

MOTOR 

SAFETY SWITCH 

Designated 

Pump Lift 

Copper Tube  

Vinyl Hose 

Evaporator 

(“A” Coil) 

Inner Ring 

92318_RevC 

MODEL: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS, CP654ULHTS 

 

 

Nut 

Check Valve 

Ball-Cage 

 

Snap Ring 

 

Ball 

 Adapter 

 

Read and Follow all Safety Instructions. 

Save This Manual for Future Reference.

 

 

CONDENSATE REMOVAL PUMP 

 

Содержание CB501ULHTS

Страница 1: ...l shock could occur Disconnect main power before handling unit for ANY REASON 5 Protect the power cable from coming in contact with sharp objects 6 Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces or chemicals 7 Make certain that line voltage conforms to the voltage specified on motor and nameplate 8 WARNING To reduce risk of electrical shock connec...

Страница 2: ...he installation removal or shipping of products subject to warranty claims DISCLAIMER AND LIMITATION THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE FULL EXTENT PERMITTED BY LAW BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANT...

Страница 3: ...e o cerca del motor y la cubierta del interruptor La bomba tiene que estar nivelada El agujero de entrada de la bomba debe por debajo del nivel de drenaje del serpentín Desempaque la bomba cuidadosamente Remueva la cubierta del interruptor Revise el rotor de cada flotador para ver si tiene acción libre TUBERÍA Instale una línea de drenaje desde el drenaje del serpentín del evaporado hasta la bomba...

Страница 4: ...N ORALES O ESCRITOS EXPRESOS O IMPLÍCITOS DE LA MANERA MAS AMPLIA QUE PERMITA LA LEY BECKETT DE MANERA EXPRESA RENUNCIA CUALQUIER Y TODAS LAS GARANTÍAS IMPLÍCITAS INCLUYENDO SIN LIMITACIÓN ALGUNA LAS GARANTÍAS IMPLÍCITAS DE COMERCIALIDAD Y USO PARA UN FIN ESPECIFICO SI LAS GARANTÍAS IMPLÍCITAS NO PUEDEN SER RENUNCIADAS TODAS LAS GARANTÍAS IMPLÍCITAS ESTÁN LIMITADAS A LA DURACIÓN DE LA GARANTÍA EXP...

Отзывы: