Becker R12/17C Скачать руководство пользователя страница 1

R12/17C...R40/17C

Version: PROF+A2

 

 

en

 

Assembly and Operating Instructions

 

 

Roller shutter drive with integrated radio receiver

915.3 Mhz

 

Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.

 

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

 

Содержание R12/17C

Страница 1: ...tter drive with integrated radio receiver 915 3 Mhz Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Ant...

Страница 2: ...onfirming the drive 11 First operation 12 Programming the master transmitter 13 Checking that the running direction is correct 13 Intelligent installation management 13 Setting the limit positions 14...

Страница 3: ...ronic system with stop systems Obstacle detection even when using anti lifting devices axle shaft devices Secure anti lifting device Slight pressure applied to the roller shutter curtain makes it diff...

Страница 4: ...g in the limit position O with sensitive obstacle detection SMI Standard Motor Interface with R with automatic detection of anti lifting devices with S higher closing force for cassette awnings Softwa...

Страница 5: ...rty damage and personal injury Please keep these instructions in a safe place Caution Important safety instructions for the user Failure to observe these instructions can lead to serious injuries All...

Страница 6: ...proved by us are prohibited We do not accept liability for dam ages or injury arising from such actions Before installation shut down all lines and control devices that are not essential for operation...

Страница 7: ...ety of the users and others since these actions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or...

Страница 8: ...onnecting cable must be disconnected On drives with a diameter 45 or 58 insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug f...

Страница 9: ...ops in the guide tracks Calculate the space required at the side M by measuring the drive head and wall bracket The clear dimension of the box X minus the space required at the side M and idler G give...

Страница 10: ...x 12 screw 3 with appropriate washer 2 and suitable screw retainer Threaded hole 4 Securing the drive against axial displacement 10 mm In order to secure the drive against axial displacement we recomm...

Страница 11: ...into the tube to achieve a form fit Ensure that the thrust ring and drive adapter are secure in the tube Mount the assembled unit comprising barrel tubular drive and idler on the box and secure the dr...

Страница 12: ...programming Readying the tubular drive for programming by switching on the power Switch on the power The tubular drive is ready to programme for 3 minutes Note If several tubular drives are to be con...

Страница 13: ...n Direction switch is OK If the shading solution runs in the wrong direction the running direction must be switched Proceed as follows Switch the direction switch 1 to the opposite position The shutte...

Страница 14: ...stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times Upper stop to lower stop Open to the permanent upper stop The tubular dri...

Страница 15: ...nge of travel Attention When both or individual limit positions are deleted all the other set functions intermediate position I inter mediate position II upper anti freeze mechanism obstacle detection...

Страница 16: ...ions Each travel button can be assigned one intermediate position Both limit positions must be set be fore the intermediate position is set When both or individual limit positions are deleted both int...

Страница 17: ...be deleted It can only be overwritten see Programming the master transmitter 13 Press the programming button on the master transmitter for 3 seconds The tubular drive makes a click sound to confirm N...

Страница 18: ...to the outside position N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Switch off the tubular drive power for 5 seconds then switch it back on The tubular drive is ready to programme for 3 minutes 1 blue 3 blac...

Страница 19: ...he shading solution to the upper limit position Press the programming button on the master transmitter for approx 3 seconds The tubular drive makes a click sound to confirm Then re press the programmi...

Страница 20: ...UP buttons for ap prox 3 seconds The tubular drive clicks 3 times to confirm Programming the run times Note This function is only available with MemoControl transmitters from the Becker Centronic ran...

Страница 21: ...regulations on recy cling or disposal for this product in your country The packaging material must be disposed of properly Maintenance These drives are maintenance free Technical data dia 45 Type R12...

Страница 22: ...ction then continue in the desired di rection Tubular drive is overloaded Use a higher torque tubular drive Switching times cannot be set on tubular drive Programmed transmitter has no manual auto sli...

Страница 23: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 23...

Страница 24: ...Declaration of conformity 24...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...2010 300 570 0a 06 03 2013...