Central, group and individual control using Centronic UnitControl UC42

Mains 230 V / 50 Hz

Central

Group

Individual

Individual

230 V / 50 Hz

Central cable

(connection to further control units)

230 V / 50 Hz

230 V / 50 Hz

E

le

c

tr

o

n

ic

s

230 V / 50 Hz

Control unit

20

Содержание R12 17C PR+

Страница 1: ...s Tubular drives for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Страница 2: ...ive adapter with drive adapter safety catch 8 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia 45 9 Mounting the drive in the tube 9 Setting the limit positions with switches 10 Deleting the limit positions using the switches 12 Setting the limit positions using the programming unit 13 Deleting the limit...

Страница 3: ...nufacturer s control units can be used For plug in connecting cable Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 24th calendar week in 2012 Ser No 1224XXXXX Explanation of...

Страница 4: ...nstructions in EN 60335 2 97 Please note that this list of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the d...

Страница 5: ...its are operated certain components e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technolo gical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushin...

Страница 6: ...tem s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Attention Only use anti lifting devices...

Страница 7: ...wer supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 1 2 A A locating latch 7 ...

Страница 8: ...bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system Attention When using rigid shaft connectors closed brackets must be fitted The tubular drive presses the closed curtain down to make it difficult for people to reach under it or raise it Only use curtains made of sufficiently ...

Страница 9: ...s for drive adapter 4 pc dia 45 50 70 mm plastic drive adapter 25 Self tapping screw dia 4 8 x 9 5 mm dia 45 50 85 mm plastic drive adapter for obstacle detection 40 Self tapping screw dia 4 8 x 9 5 mm dia 45 50 85 mm diecast drive adapter 50 Self tapping screw dia 4 8 x 9 5 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into the tube or drop it int...

Страница 10: ...d you use at least three for longer tubes use three springs anti lifting devices per meter of barrel Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges Setting the limit positions with switches Setting the limit positions There are 3 ways to set the limit positions L...

Страница 11: ...open to the desired upper limit position Now reset the switch of the UP direction of rotation from the delete setting to the pro gramming setting The limit positions are now set Lower point to upper stop Set both switches to the delete setting Execute a short drive command Close to the desired lower limit position Reset the switch of the DOWN direction of rotation from the delete setting to the pr...

Страница 12: ...ons are now set Deleting the limit positions using the switches Deleting individual limit positions It is possible to delete an individual limit position if lower point to upper point without stops has been programmed with the switches Reset the switch of the corresponding limit position from the programming setting to the delete setting Execute a short drive command The limit position is now dele...

Страница 13: ...ening closing again Attention The switch is not suitable for continuous operation and has only been designed for start up Programming setting Switch Delete setting Direction arrows Programming button Travel button Connect the wires of the tubular drive to those of the same colour in the programming unit Item No 4935 200 011 0 and switch on the power supply Lower point to upper point without stops ...

Страница 14: ...hes to the programming setting Close to the lower limit position The tubular drive switches off automatically Then open to the permanent upper stop The tubular drive switches off automatically The limit positions are now set Anti lifting device in the lower limit position to upper point without stops Set both switches to the programming setting Close to the lower limit position The tubular drive s...

Страница 15: ...eletion sequence Deleting a limit position when 2 limit positions are programmed black brown blue green yellow black brown blue green yellow Programming button Travel button Open close to the limit position to be deleted Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pr...

Страница 16: ...ng the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 Attention Only use mechanically or electrically locked switching elements with a marked zero posi tion This also applies when drives with electronic and mechanical limit switching are used in the same system The changeover time for switching the running direction must be at lea...

Страница 17: ...7C PR Rated torque Nm 8 12 20 30 37 Output speed rpm 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 230 Rated current consumption A 0 45 0 50 0 75 0 90 1 18 Mode S2 4 min Degree of protection IP 44 Min tube inside diameter mm 47 Emission sound pressure level dB A 70 17 ...

Страница 18: ...s not work even after standing still for a long period of time Replace the tubular drive press the reset button on the programming unit No click ing sound emergency programme tu bular drive can be opened and closed for dismounting using the programming unit Tubular drive switched off the last time it went in that direction because of a block age Clear and remove the blockage and set the drive in t...

Страница 19: ...lack and brown wires according to the direction of travel is de pendant on how the drive is installed mounted to the right or to the left Controlling one several drive s via a single switch button Controls black brown blue green yellow Controls 19 ...

Страница 20: ...dual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 20 ...

Страница 21: ...Declaration of conformity 21 ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...2010 300 326 0e 11 07 2016 ...