Becker PA3-2AB-AIR Скачать руководство пользователя страница 4

        ENVIRONMENTAL CHARACTERISTICS 

Parameter 

Symbol 

Min 

Typ 

Max 

Unit 

Condition 

Operating Temperature 

T

O

 

-20 

+60 

°C 

Storage Temperature 

T

S

 

-40 

+85 

°C 

Operating Humidity 

H

O

 

85 

relative, non-condensing 

Storage Humidity 

H

S

 

95 

relative, non-condensing 

        MECHANICAL PROPERTIES 

Parameter 

Value 

Units 

Limits 

Condition 

Dimensions 

7

.5” W x 

2.2

” H x 

3.7

” D 

inch 

max 

Weight 

lb 

max 

RF Connectors  In /Out 

BNC / T

NC

” 

Cooling 

Convection 

Vibration 

Sinusoidal, 0.35mm -5G, 10 – 150 Hz 

max 

IEC/EN 60068-2-6 

Random Vibration 

From 20 to 500Hz - 5G 

max 

IEC/EN 60068-2-64 

Shock 

Half-Sine, 11ms(±.5ms) – 15G, in each plane 

max 

IEC/EN 60068-2-27 

III. OPTIONS

The Air Band VHF Mobile Power Amplifiers

 are available with several options: input, output, fre-

quency ranges and configurations,

 cases,

 special logos, etc., when specified at the time of order. We 

work closely with you, our customer, to develop products that are in complete compliance with your 
needs and specifications. 

IV. CAUTION!

EXPENSIVE  COMPONENTS  MAY  BE  DESTROYED  IF  THE  AMPLIFIER  IS  TURNED  ON  IN  A 

DAMAGE CONDICTION. 

Содержание PA3-2AB-AIR

Страница 1: ...AIR lnstallation and Operation Manual Issue 1 DV PA3 2AB AIR 1 March 2016 BECKER AVIONICS INC 10376 USA Today Way Miramar FL 33025 USA Telephone 1 954 450 3137 Fax 1 954 450 3206 http www beckerusa co...

Страница 2: ...TABLE OF CONTENTS I PRODUCT DESCRIPTION II GENERAL SPECIFICATION III OPTIONS IV CAUTION V OPERATING PRECAUTIONS VI INSTALLATION VII WARRANTY VIII SERVICE...

Страница 3: ...GENERAL SPECIFICATIONS The general specifications for the VHF amplifier are shown in this section Typ Max Unit Condition Frequency Range BW 118 138 MHz Operating bandwidth within range OBW 20 MHz Inp...

Страница 4: ...ration Sinusoidal 0 35mm 5G 10 150 Hz max IEC EN 60068 2 6 Random Vibration From 20 to 500Hz 5G max IEC EN 60068 2 64 Shock Half Sine 11ms 5ms 15G in each plane max IEC EN 60068 2 27 III OPTIONS The A...

Страница 5: ...ly be placed over it Keep duty cycle below limits TERMINATIONS The efficiency of this amplifier will degrade if it is operates into anything but a 50 load Lowered efficiency may mean any or all of the...

Страница 6: ...g Use 12 AWG if possible and certainly no lighter than 14 AWG To avoid a possible fire or other possible damage make sure a fuse or circuit breaker is installed at the battery end of the wire Attach D...

Страница 7: ...inal with a 50 coaxial cable and a TNC male connector according to figure 4 Turn off your radio transceiver Connect it to the RF INPUT terminal with a 50 coaxial cable and a BNC male connector Figure...

Страница 8: ......

Страница 9: ...vered by the owner to the factory intact The warranty does not apply to any product which as been subjected to misuse neglect accident improper installation or used in violation of the instructions fu...