Deleting all transmitters (except the master transmitter)
3s
Press the programming button on the master transmitter for 3 seconds.
▻
The tubular drive acknowledges.
3s
Re-press the programming button on the master transmitter for 3 seconds.
▻
The tubular drive acknowledges.
10s
Re-press the programming button on the master transmitter for 10 seconds.
▻
The tubular drive acknowledges.
►
All transmitters (except the master transmitter) are now deleted from the re-
ceiver.
Overwriting the master
There are two ways to overwrite the master:
•
Readying the tubular drive for programming by switching on the power
•
Readying the tubular drive for programming with the radio switch
Readying the tubular drive for programming by switching on the power
To ensure that the new master transmitter is programmed in the desired tubular drive only,
all other tubular drives which are connected to the same power supply must be deactivated
from the programming mode. To do so, after switching back on the power, execute a drive
or stop command using the transmitter for the given tubular drives or switch the radio
switch from inside to outside. If the radio switch is already in this position, switch it to the
inside and back to the outside position.
N
1
2
1
2
4
3
4
230V AC / 50 Hz
L1
PE
Switch off the tubular drive power for 5 seconds, then switch it back on.
▻
The tubular drive is ready to program for 3 minutes.
1 = blue
3 = black
2 = brown
4 = green/yellow
10s
Now press the programming button of the new master transmitter for 10 seconds.
▻
The tubular drive acknowledges.
►
The new master transmitter has now been programmed and the old master trans-
mitter overwritten.
Readying the tubular drive for programming with the radio switch
Switch the radio switch to the inside position. If the radio switch is already in this posi-
tion, switch it to the outside and back to the inside position.
▻
The tubular drive is ready to program for 3 minutes.
10s
Now press the programming button of the new master transmitter for 10 seconds.
▻
The tubular drive acknowledges.
►
The new master transmitter has now been programmed and the old master
transmitter overwritten.