Becker GK61 Series Скачать руководство пользователя страница 2

 

Quick Start Guide 

  

Portable VHF Stations GK61X  

 

0646.921-071 Issue 03 08/2015 

We reserve the right to make technical changes. The data correspond to the current status at the time of printing. 

 

 

Figure: Rear view GK61X 

Figure: Wiring Diagram Connector P2 

Start-Up 

 Connect the antenna and the mike/speaker to the corresponding jacks 

 Turn "ON" the device by turning the volume knob clockwise. 

 During PBIT (Power-On Built In Test) the display indicates the message "WAIT", the 

software version of "Control Head" (CH) and the software version of "Chassis 

Module" (CM). 

 If the PBIT has detected error(s),"FAILURE" appears on the display. 

For Operation, see 

"Quick Start Guide VHF Transceiver Family 620X"

 

Technical Data GK61X 

DC Supply voltage 

10...32 V 

Nominal supply voltage 

12 V / 24 V 

Fuse  

2 A (GK61X-XX), 7 A (AR620X-XXX/GT6201-XX) 

Mike/Headphone 

Dyn. Mike 2...10 mV, Headphone 40 mW / 300 

Ω

 

Antenna impedance 

50 

Ω

 

Battery capacity 

2 Ah / 12 V (GK615-XX), 2x 2 Ah / 12 V (GK616-XX) 

 

Storage 

 

The batteries have a self-discharge of approx. 1% per day. We 

recommend to recharge the batteries every 3 month of storage. 

Use delivered power cable. 

  

Отзывы: