Technical data dia. 45
Tubular drive
R8-17
R12-17
R20-17
R30-17
R40-17
Model
E16-V1
Type
C SEO I3
Rated torque [Nm]
8
12
20
30
40
Output speed [rpm]
17
17
17
17
17
Limit switch range
64 revolutions
Supply voltage
230 V AC / 50 Hz
Connected load [W]
100
110
160
205
260
Rated current consumption [A]
0.45
0.50
0.75
0.90
1.15
Operating mode
S2 4 min
Degree of protection
IP 44
Min. tube inside diameter [mm]
47
Emission sound pressure level
[dB(A)]
≤ 70
What to do if...?
Problem
Remedy
Tubular drive overruns the limit position or does not reach the
set limit position.
Check electrical installation; remove external devices; reset
limit positions.
Due to long cable, L1 and N connection have been reversed.
Change around L1 and N (N = blue, L1 = black/brown); reset
limit positions.
Repair system; delete limit positions, then re-program limit po-
sitions.
Tubular drive stops arbitrarily; cannot be restarted in the same
direction.
Use a more powerful tubular drive.
Ensure that the sun protection system runs smoothly.
Delete limit positions, then re-program limit positions.
Tubular drive does not run in the right direction.
Tubular drive is overheated. The tubular drive is operational
again after a few minutes.
Clear and remove the obstruction and set the drive in the direc-
tion required.
Check the electrical connection.
Repair electrical installation and re-program limit positions.
Tubular drive only runs for approx. 1 second.
Tubular drive is faulty. Replace the tubular drive.