Programming intermediate positions I
+ II in Venetian blind operation
If an intermediate position II (tilt position) has been pro-
grammed, the blind will automatically travel to this position
by double-tapping DOWN in the limit position (once the run-
ning time has elapsed). If an intermediate position I has also
been programmed, the blind is tilted as soon as intermediate
position I is reached.
Application
Function
Venetian blind operation
Tilting
Intermediate position II (tilt position)
This function lets you move the Venetian blind up again from
the lower limit position until the desired intermediate posi-
tion II is reached. Both limit positions must be set before in-
termediate position II is set.
Programming intermediate position II (tilt position)
Move the blind from the lower limit position to the desired intermediate posi-
tion II.
First press and hold the STOP button and, within the next 3 seconds, press
and hold the UP button. Keep both buttons depressed until
▻
the receiver confirms.
►
Intermediate position II is now saved.
Checking intermediate position II (tilt position)
Press the UP button twice within one second.
►
The blind moves to intermediate position II.