Technical data
Rated voltage
230–240 V AC / 50 Hz
Degree of protection
IP 20
Class of protection
(dependent on correct assembly)
II
Permissible ambient temperature
0 to +55°C
Type of mounting
Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing
Maximum emitted transmission out-
put
≤ 25 mW
Radio frequency
868.3 MHz
The maximum transmitter range on and in the building is up to 25 m, and up to
350 m in the open.
What to do if...?
Problem
Remedy
Drive not functioning, transmission
pilot light remains off.
Check connection.
Drive is running in the wrong direc-
tion.
Swap the and wires on the flush-
mounted radio transmitter.
Drive not functioning, transmission
pilot light lights up.
Receiver out of radio range. Reduce
distance from receiver.
Transmitter is not programmed into
receiver. Program transmitter.
20 - en