Drive controller
If the UCR520 is used as a drive controller, the drive is connected directly to
the device. External signals are converted into control commands. The coding
switch 2 must be in the lower position.
Group controller
If the UCR520 is used as a group controller, other group controllers/drive con-
trollers can be controlled. This control can relay external switching signals.
This function can be used to connect groups and carry out joint switching com-
mands. The coding switch 2 must be in the upper position.
Settings
Roller shutter or venetian blind
Encoding Switch 3 is used to select roller shutter mode (lower position) or vene-
tian blind mode (upper position). When the venetian blind mode is selected,
the venetian blind moves in nonmaintained command mode in order to allow
for the blind slats to be positioned precisely. If a control command button is
held pressed for more than 1 second, the venetian blind will move in maintained
command mode.
Functions
Functions in manual mode (on the device and via radio
control)
• UP, STOP, DOWN
• Intermediate position
• Ventilation/adjustment position
• Emergency signals
Functions in automatic mode
• External automatic drive commands
• UP, STOP, DOWN
• Intermediate position
• Ventilation/adjustment position
• Emergency signals
Содержание Centronic UnitControl UCR520
Страница 9: ...fr en de nl 9 Anzeigen und Tastenerklärung ...
Страница 21: ...fr en de nl 21 Explanation of displays and buttons ...
Страница 33: ...fr en de nl 33 Explication des textes d affichage et des touches ...
Страница 45: ...fr en de nl 45 Verklaring van displays en toetsen ...
Страница 52: ...4031 630 010 0b 12 10 309155 02 ...