Venetian blind selection
With the venetian blind function, the venetian blind runs in touch mode to facil-
itate precise positioning of the laths. If you press a travel button for longer than
1 second, the venetian blind runs in maintained operation mode.
After moving to the programmed intermediate and end positions, the laths
automatically tilt (if the tilt position was programmed).
Manual/Automatic slide switch
In slide switch position only manual drive commands can be performed
(e.g.: UP, STOP, DOWN via button actuation).
In slide switch position automatic drive commands are performed (e.g.
shade function, twilight function, time, Astro function,...)
Transmission pilot light
A radio signal is indicated by the transmission pilot light lighting up. The trans-
mission pilot light flashes while transmitting if the battery is getting weak. The
transmission strength and the radio range decrease as battery power de-
clines. If the transmission pilot light no longer lights up when a button is
pressed, the batteries must be replaced.
Group
Several receivers controlled simultaneously are referred to as a group. The
programmed group is controlled via a radio channel using a drive command.
Operating mode
On the display, you see the time and the current operating mode e.g. HOLI-
DAY.
OK button
The displayed values are saved by pressing the OK button in the menu.
+/- buttons
The following operations are possible via + and -:
•
Menu
->Modify value
•
Auto
mode ->Retrieve information:
∙
+ button ->Next automatic switching time
∙
- button ->Next automatic switching time
∙
Hold + button
and OK
button -> Astro time
∙
Hold - button
and OK
button -> Astro time