Technical data dia. 35

Tubular drive

P5-20

P5-30

P9-16

Model

C18

Type

CPSOF Z1

Rated torque [Nm]

5

5

9

Output speed [rpm]

20

30

16

Limit switch range

64 revolutions

Supply voltage

230 V AC / 50 Hz

Connected load [W]

115

115

110

Rated current consumption [A]

0.47

0.47

0.47

Operating mode

S2 4 min

Degree of protection

IP 44

Min. tube inside diameter [mm]

37

Frequency

868.3 MHz

Emission sound pressure level [dB(A)]

≤ 70

Technical data dia. 45

Tubular drive

R8-17

R12-17

R20-17

R30-17

R40-17

Model

C18

Type

CPSOF Z1

Rated torque [Nm]

8

12

20

30

40

Output speed [rpm]

17

Limit switch range

64 revolutions

Supply voltage

230 V AC / 50 Hz

Connected load [W]

100

110

160

205

260

Rated current consumption [A]

0.45

0.50

0.75

0.90

1.15

Operating mode

S2 4 min

Degree of protection

IP 44

Min. tube inside diameter [mm]

47

Frequency

868.3 MHz

Emission sound pressure level [dB(A)]

≤ 70

17 - en

Содержание C18

Страница 1: ...ted radio receiver for ZIP systems Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 901 0b 14 07 2022 ...

Страница 2: ...int to upper stop 11 Deleting the limit positions 12 Intermediate positions I II 12 Programming additional transmitters 13 Deleting transmitters 13 Overwriting the master 14 Setting the limit positions with Auto install for ZIP applications with heavy end strip 14 Obstacle detection for ZIP applications with heavy end strip 15 Local operation with a single button 15 Programming the run times 16 De...

Страница 3: ... increases the service life For plug in connecting cable Please observe these Assembly and Operating Instructions when installing and setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictogr...

Страница 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Страница 5: ... down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or protected When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 If the mains connecting cable is damaged it may only be replaced by the manufacturer If the drive has a plug in connecting cable it mu...

Страница 6: ...jury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Assembling and disassembling the plug in connecting cable Caution The power supply to...

Страница 7: ...embly the power supply must be disconnected and secured Please give the enclosed connection information to the responsible electrical contractor Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varie...

Страница 8: ...on for round shafts we recommend screwing the drive adapter to the shaft see the table below Attention When drilling into the barrel never drill near the tubular drive Size of drive mm Drive adapter Torque max Nm Fastening screws 4 units dia 35 dia 45 All Up to 50 Self tapping screw dia 4 8 x 9 5 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into t...

Страница 9: ... the thermal protection switch cuts in repeatedly N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Connecting the tubular drive Connect the tubular drive to the power supply 1 blue 3 black 2 brown 4 green yellow Readying the tubular drive for programming Readying the tubular drive for programming by switching on the power Switch on the power The tubular drive is ready to programme for 3 minutes If several tubu...

Страница 10: ...otation via the direction switch Press the or button The shading solution runs in the desired direction The running direction is OK If the shading solution runs in the wrong direction the running direction must be changed Proceed as follows Switch the direction switch 1 to the opposite position The running direction will now have changed Check the running direction again Changing direction of rota...

Страница 11: ...struction The desired limit position can be set by opening or closing again There are several ways to set the limit positions Lower point to upper point Lower point to upper stop Auto install The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times Lower point to upper point There is no shading solution length adjustment with this li...

Страница 12: ...nd within the next 3 seconds press the STOP button at the same time and hold the two buttons down for 10 seconds The tubular drive acknowledges The limit positions are now deleted Intermediate positions I II The intermediate positions I II are freely selectable positions for the shading solution between the two limit positions Each travel button can be assigned one intermediate posi tion Both limi...

Страница 13: ...mitter has now been programmed Deleting transmitters Deleting individual transmitters The programmed master transmitter cannot be deleted It can only be overwritten see Programming the master transmitter 10 3s Press the programming button on the master transmitter for 3 seconds The tubular drive acknowledges 3s Now press the programming button of the transmitter to be deleted for 3 seconds The tub...

Страница 14: ...r for 10 seconds The tubular drive acknowledges The new master transmitter has now been programmed and the old master trans mitter overwritten Readying the tubular drive for programming with the radio switch Switch the radio switch to the inside position If the radio switch is already in this posi tion switch it to the outside and back to the inside position The tubular drive is ready to program f...

Страница 15: ...rive is correctly installed it switches off when it detects obstructions or fabric faults and tries to run past the obstruction a second time If this fails the drive switches off after the third attempt Approx 360 from the lower limit position the drive interrupts operation immediately following the first detection of an obstacle and makes no further attempt to continue The total number of attempt...

Страница 16: ...el Deleting the run times When deleting both run times are always deleted To delete the UP and DOWN run time press the STOP button for 10 seconds The tubular drive makes a click click sound to con firm The run times are now deleted Activating deactivating the additional fabric untensioning function with the master transmitter The to upper stop limit position must be set for the fabric untensioning...

Страница 17: ...inside diameter mm 37 Frequency 868 3 MHz Emission sound pressure level dB A 70 Technical data dia 45 Tubular drive R8 17 R12 17 R20 17 R30 17 R40 17 Model C18 Type CPSOF Z1 Rated torque Nm 8 12 20 30 40 Output speed rpm 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 50 0 75 0 90 1 15 Operating mode S2 4 mi...

Страница 18: ...delete limit positions then reprogram limit positions Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive is overloaded Use a higher torque tubular drive Ensure that the system runs smoothly Tubular drive does not run in the right direction Tubular drive is overheated The tubular drive is operational again after a few minutes Tubular drive is faulty does not run...

Страница 19: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 19 en ...

Страница 20: ...Declaration of conformity 20 en ...

Страница 21: ...21 ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ......

Отзывы: