Changing the set limit positions
Once set, the limit positions can only be changed with the master transmitter.
1) Shortening the range of travel (the desired limit position is located inside the current range of
travel)
Open/close to the desired new limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
for the lower limit position or the UP button for the upper limit position and hold the
two buttons down.
▻
The tubular drive acknowledges.
►
The new limit position is now saved.
2) Extending the range of travel (the desired limit position is located outside the current range of
travel)
Attention
When both or individual limit positions are deleted, all the other set functions (intermediate
position I, intermediate position II, upper anti-freeze mechanism, obstacle detection, run
times, fly screen protection function) are deleted as well.
Open/close to the limit position in the direction in which you wish to extend the range
of travel.
Press the programming button and, within 3 seconds, also press the STOP button
and hold the two buttons down for 10 seconds.
▻
The tubular drive acknowledges.
►
The limit position is now deleted.
Open/close to the desired new limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
for the lower limit position or the UP button for the upper limit position and hold the
two buttons down.
▻
The tubular drive acknowledges.
►
The new limit position is now saved.