Info
In Info mode, information is provided in the following order:
Day – Time – Software version – KNX software version – Battery voltage
Example:
DI – 13H29 – ST 1-13 – KNX 2-02 – BATT 3-23V
You can access "INFO" mode as follows:
1.
To wake up the device, press the "+" or "-" button until the display
switches on automatically.
2.
Press the "+" and "-" buttons simultaneously until the message "LINK"
appears on the display for the program standby state.
3.
Press the "+" or "-" button until the message "INFO" appears on the dis-
play.
The "INFO" mode can be cancelled by changing to a different mode by briefly
pressing the "+" or "-" button. If no button is pressed, the device attempts to
re-adapt itself after 3 minutes and then reverts to the operating status.
Restoring to factory settings
Before resetting the device to factory settings, you must
clear it in all operator units.
1.
Remove all batteries (see chapter Changing batteries [
sert them shortly afterwards, then wait until the message "LINK" or
"OPEN" appears on the display.
2.
Press and hold the "+" and "-" buttons simultaneously until the message
"ADJ" appears on the display. The heating actuator adapts itself and
changes to normal mode.
3.
Press and hold the "+" and "-" buttons simultaneously until the message
"OPEN" or "LINK" appears on the display and the control unit has coun-
ted down from 10 to 0.
4.
"----" now appears on the display.
5.
You can now release the "+" and "-" buttons.
6.
The factory setting for the control unit has now been restored.
16