Programming the run times
1.
The tubular drive must be in the upper limit position to program the
DOWN run time, and must be in the lower limit position for the UP run
time.
2.
Wait for the time you wish the automatic drive command to be executed.
3.
At the desired time, press and hold the relevant direction button until the
tubular drive briefly stops after approx. 6 seconds and then continues to
the limit position.
4.
Release the direction button.
The tubular drive has saved the current time for this direction of travel.
Proceed in exactly the same way with the other direction of movement.
Deleting the run times
When deleting, both run times are always deleted.
To delete the UP and DOWN run time, press the STOP button for 10 seconds.
The tubular drive makes a "click click" sound to confirm.
The run times are now deleted.
Upper anti-freeze mechanism
The upper anti-freeze mechanism (if present in the receiver) helps to prevent
the roller shutter from freezing in the upper limit position, as the roller shutter
stops just before the upper stop. The distance from the upper stop is automat-
ically cyclically checked and, if necessary, corrected.
The upper anti-freeze mechanism is deactivated on delivery.
Both limit positions must be set before the anti-freeze mechanism can be ac-
tivated.
The anti-freeze mechanism only works if a permanent stop is
set at the upper limit position of the roller shutter. The anti-
freeze mechanism is not visible until the shading solution has
reached the upper stop from the lower limit position 3 times
in succession.
When both or individual limit positions are deleted, this set
function is deleted as well.
22
Содержание B-Tronic EasyControl EC5415B