Operating Instructions
21
b) Point when canopy is extended to end stop
Move both switches to the reset position.
Press the control command briefly.
Move the canopy to the required end limit when extended.
Move the switch with the rotation arrow for extending the canopy from the reset position to
the programming position.
Then move the canopy up to the upper, permanent end stop until the tubular drive switches
off automatically.
The end limits are set.
a) Deleting the end limits individually
Note
It is only possible to delete an individual limit stop if the point when the
canopy is extended to the point when the canopy is retracted without end
stop has been programmed using the switches.
Move the switch for the relevant end limit from the programming position to the reset
position.
Deleting the end limits using the switches
Press the control command briefly.
The end limit is deleted.
Press the control command briefly.
b) Deleting both end limits
Move both switches from the programming position to the reset position.
Both end limits are deleted.