Rev 1
Copyright © 2021 by BECCA Inc. All Rights Reserved.
BECCA Recycler Operators Guide Poster 831240
6. Push the Red button. The cycle is now initiated. The system display will show:
Set Temperature Set Time Elapsed Time
7. We recommend not opening the unit after the cycle is completed
for 1
– 3 ½ Hours or the Temperature is below 200 °F (Depends on
temperature, time, and the amount of solid waste). This allows the
unit to cool down.
8.
The resulting ‘Still Bottom’ will range in consistency from slurry to
a marshmallow. All of this is again dependant on the types of
solvents, type of
paint, and the painter’s waste levels and Recycler
settings (Time & Temperature).
9.
Dispose of the ‘Still Bottom’ in an approved
Hazardous Waste container and assure
proper labeling.
10. a) For Manual Systems switch out full
“Recycled Solvent” container for the
empty at the Gun Washer.
b) For Direct Connect Systems review
levels in each tank
11. You are now ready for the next cycle of the process.
3) Troubleshooting
1.
Error Code “L Hi” – Liquid Temperature from
condenser is too hot. See “Instruction Manual”
2.
Error Code “O Hi” – Oil Temperature is too hot. See
“Instruction Manual”
3. Weak Solvent
– This is from the Spray Gun Cleaning
process causing evaporation of “Acetone”. Add
“Acetone” – typical solvent used in Gun Cleaning
formulations that starts to evaporate at 80ºF and Boils
at 130ºF.
4. The Lid Seal
– Seals absorb and desorb solvent in the distillation process.
Removing the lid prior to cooling below 170ºF will cause the seal to swell
and pop out of the lid. Please go to
our
“How To” video on seal replacement.
4) Maintenance
1. Each Use - Replace Recycler Bag. Use only BECCA Recycler
Bags to assure performance (630003 for 3
Gallon & 660006 for 6 Gallon)
- Remove any contaminants from the
bottom of the Boiler
2. Each day - Wipe-down the unit with solvent. The paint and
decals are solvent resistant.
- Remove any contaminants from the
bottom of the Boiler
3. Semi-Annually
– Blow off condenser (externally) to
remove dust and dirt
-
Replace BECCA Protect™ Maintenance
Coating (ECP 831004)
- Review Ground Clamp (823079)
5. Annually - Replace Seal (804008 for 3 Gallon) (804018 for 6 Gallon)
- Blow out Condenser (internally)
- Change Oil (630066)
-Review & Replace any illegible or damaged Decals
-Complete Electrical Diagnostic
For assistance or service Phone or Fax:
Tel: (800) 655-5649
Fax: (800) 655-5684
4H00
360°F
1H32